User's Manual

Table Of Contents
Configuring and Operating the Orion Reader Using TCP Commands
Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document. 6-5
10 Set Data Detect This command sets the data detect value for a specific tag
protocol: ISO 18000-6C (EPC), Title 21, IAG, or CVISN. This
value is an independent detection threshold level for backscatter
protocols of up to 20dB. Data Detect can be incremented or
decremented in 1dB steps through the command interface port.
The threshold level for CVISN is 15 dB.
11 Set Seen Count and
Uniqueness Count
This command sets a counter that records the number of times a
tag is read after the system had finished a complete transaction.
13 Set Time and Date This command sets the Orion Reader real-time clock to the time
and date specified in the request data.
14 Set Line Loss This command sets the Orion Reader system line loss value
from 0 to 3 decibels (dB) in 1-dB increments via the command
interface port. This command must be set only after RF
attenuation is set.
15 Set Manual Antenna
Channel
This command sets the antenna channel.
16 Set Antenna Multiplexer
Configuration Data
This command selects the antenna multiplexer mode.
18 Set IAG Slot This command sets the IAG trigger pulse slot, which allows
multiple readers to have non-overlapping IAG time slots.
19 Append Time-stamp This command is optional.
21 Set Mode This command sets the Orion Reader to Mode 88.
Set Protocol(s), Set Secondary Tag Sequence, and Reset commands must be transmitted in
the order shown in table.
Table 6-1 Commands Used to Configure Orion Reader in Mode 88
Sequence # Command Definition