User's Manual

Table Of Contents
Configuring and Operating the Orion Reader Using TCP Commands
Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document. 6-25
The Buffered Tag Transaction Number field specifies the number of the buffered tag
transactions to be retrieved. The data values for this field range from 01H to
0FFFFFFFFH.
The Buffered Tag Transaction Data field contains the buffered tag transaction
response data that has a maximum byte length of 57.
Get Number of BufferedTagTransactions
This command gets the number of buffered tag transactions that are stored in the
reader. Table 6-22 and Table 6-23 list the command and response data.
The buffered tag transaction overflow status is returned as 0 for no overflow or 1 for
overflow. The Number of Buffered Tag Transactions field specifies the current num-
ber of buffered tag transactions. The data values for this field range from 0H to
0FFFFFFFFH. Using the TCP command set, the Orion Reader can store up to
500,000 tag IDs in the buffer and the buffered tag information is saved upon reader
reset. The data values for this field range from 0H to 0FFFFFFFFH.
Table 6-21 Get BufferedTagTransaction Response
Get BufferedTagTransaction Response Data Data Payload
Get Buffered Tag Transaction Command 0007H
Buffered Tag Transaction Number (MSW) XXXXH
Buffered Tag Transaction Number (LSW) XXXXH
Buffered Tag Transaction Data
Table 6-22 Get Number of BufferedTagTransactions Command (0008H)
Get Number of BufferedTagTransactions Command Data Data Payload
Get Number of Buffered Tag Transactions Command 0008H
Table 6-23 Get Number of BufferedTagTransactions Response Data
Get Number of BufferedTagTransactions Response Data Data Payload
Get Number of Buffered Tag Transactions Command 0008H
Number of Buffered Tag Transactions (MSW) XXXXH
Number of Buffered Tag Transactions (LSW) XXXXH
Buffered Tag Transaction Overflow Status:0=nooverflow,1=overflow
XXH