User's Manual

Table Of Contents
Orion Reader System Guide
6-30 Use or disclosure of Proprietary Information contained on this sheet is subject to the restriction stated on the title page of this document.
Table 6-41 lists the response protocols.
Set Switch Buffered TagTransaction Mode Enable
This command sets the switch buffered tag transaction mode enable in the reader. The
enable control byte is returned as 0 for disabled or 1 for enabled. Table 6-42 and Table
6-43 list the command and response data.
Get Switch Buffered TagTransaction Mode Enable
This command gets the switch buffered tag transaction mode enable from the reader.
The enable control byte is returned as 0 for disabled or 1 for enabled. Table 6-44 and
Table 6-45 list the command and response data.
Time-out Period in ms (LSB) XXH
Table 6-40 Get AcknowledgeTime-out Period Response Data
Table 6-41 Get AcknowledgeTime-out Period Communication Protocols
Communication Protocol Data Code
TCP/IP Communication 01H
Serial Communication 02H
Serial Debug Communication 03H
Table 6-42 Set Switch Buffered Tag Transaction Mode Enable Command (001AH)
Set Switch Buffered TagTransaction Mode Enable Command Data Data Payload
Set Switch Buffered Tag Transaction Mode Enable Command 001AH
Enable Control Byte: 0 = Disabled, 1 = Enabled XXH
Table 6-43 Set Switch Buffered Tag Transaction Mode Enable Response
Set Switch Buffered TagTransaction Mode Enable Response Data Data Payload
Set Switch Buffered Tag Transaction Mode Enable Command 001AH
Table 6-44 Get Switch Buffered Tag Transaction Mode Enable Command (001BH)
Get Switch Buffered TagTransaction Mode Enable Command Data
Data Payload
Get Switch Buffered Tag Transaction Mode Enable Command 001BH