Manual

2
© Copyright 2013. All rights reserved.
MODELS: C D E F
ITEM DESCRIPTION QTY
4/96
thru
10/05
11/05
thru
9/10
10/10
thru
5/13
6/13
thru
Current
1 DC backup pump 1 010475 017198 017198 017198
2 Plastic battery box 1 005702 005702 005702 005702
3 DC control charger with terminals 1 152907 152907 152907 152907
4 “Off”/”On” oat switch 1 017197 017197 017197 017197
5 1½" x 5" long PVC pipe nipple 1 005639 N/A N/A N/A
6 Check valve (2) REV C - (1) REV D 005636 005636 019768 019768
7 Reducer hose coupling and clamp 1 30-0188 N/A N/A N/A
8 1¼" x 1" PVC reducer tting 1 005642 N/A N/A N/A
9 1" pipe to hose adapter elbow 1 005643 N/A N/A N/A
10 1" hose coupling and two clamps 1 005703 N/A N/A N/A
11 1½" PVC pipe tee 1 005645 005645 005645 005645
12 1½" 90 degree PVC pipe elbow 1 005644 N/A N/A N/A
13 1¼" x 1¼" PVC coupling 1 009129 N/A N/A N/A
14
Pump mounting kit, includes brkt, S.S. worm
drive clamp, two #10-24 screws and washers.
1 005704 N/A N/A N/A
15 Cable tie 1 005868 N/A N/A N/A
16 Anchors, Wall 2 009691 009691 009691 N/A
17 Bracket, control mounting 1 007779 007779 007779 N/A
18 1½" x 1½" PVC coupling 1 N/A 009746 N/A N/A
19 Clamp, H28 55 zinc-plated screw 1 012724 012724 012724 012724
20 Fuse, Agc - 15 amp 1 N/A 012352 012352 012352
The DC emergency pump system requires a good quality, 12
volt battery to obtain maximum pumping time during a power
outage. A deep-cycle, 12 volt, 105 amp-hour marine battery or
larger is recommended and will provide approximately 7½ hours
of continuous pumping time in a sump pump installation with 8' of
head pressure. In most installations the pump runs intermittently
and the battery life is extended accordingly. Batteries with top
terminals are recommended for ease of installation. These batteries
contain acid and proper precaution must be taken when handling.
Maximum battery size 13½" Length x 7" Width x 9½" Height.
DESCRIPTION
The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary
pump failure. The DC pump, electronic controls and all the parts required for installation are included except the battery which
is supplied by the user. The system is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18"
x 22" applications, consult factory.
REPLACEMENT PARTS LIST
PERFORMANCE
BATTERY SELECTION
The DC pump performance with fully charged 12V battery
Discharge
Feet of head
5 10 15 17.5
Flow GPM 23 15 5 Shut-off Head
The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery
after use when AC power is restored. Time for recharge depends upon the amount of power consumed by the pumping cycle
during the AC power interruption. The pump may go back to the ready run position in a very short period of time. A completely
drained battery may require up to 24 hours for full recharge.
2
12 VOLT BATTERY
SUPPLIED BY USER
1
19
4
20
3
6
11
SK2981