DRAINMAKER
INSTALLATION IN STRUC TIONS
PREINSTALLATION CHECK LIST
1. To reduce the risk of elec tri cal shock, a prop er ly ground ed
receptacle of grounding type must be in stalled and pro tect ed
by a ground fault circuit in ter rupt er (GFCI) and in ac cor dance
with National Electrical Code and lo cal codes.
2. Make certain that the receptacle is with in the reach of the pump’s
pow er supply cord. DO NOT USE AN EX TEN SION CORD.
Extension cords that are too long or too light do not deliver
suf cient voltage to the pump motor. But more im por tant, they
could present a safety hazard if the insulation were to become
damaged or the con nec tion end were to fall into the sump.
3. Testing for Ground. As a safety mea sure, each elec tri cal outlet
should be checked for ground using an Un der writ ers Lab o ra to ry
Listed circuit analyzer which will in di cate if the pow er, neutral
and ground wires are correctly con nect ed to your out let. If they
are not, call a qualifi ed elec tri cian.
4. For Added Safety. Pump must be con nect ed to a 3-prong
ground ed outlet in ter rupt er de vice (ground fault cir cuit in ter -
rupt er).
5. FOR YOUR PROTECTION, ALWAYS DIS CON NECT PUMP
FROM ITS POWER SOURCE BEFORE HAN DLING. Sin gle
phase pumps are supplied with a 3-prong ground ed plug to help
protect you against the pos si bil i ty of elec tri cal shock. DO NOT,
UNDER ANY CIR CUM STANC ES, RE MOVE THE GROUND
PIN. To re duce the risk of electrical shock, a properly grounded
re cep ta cle of ground ing type must be installed and pro tect ed
by a ground fault circuit interrupter (GFCI) in ac cor dance with
national elec tri cal code and local codes.
6. Installation and checking of electrical cir cuits and hard ware
should only be performed by a qualifi ed licensed electrician.
7. Risk of electric shock - These pumps have not been in ves ti gat ed
for use in swimming pool areas.
8. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
1. Check to be sure your power source is adequate for handling
the voltage requirements of the motor, as in di cat ed on the
pump or basin plate.
2. Make sure the pump electrical supply cir cuit is equipped with
fuses or circuit breakers of proper ca pac i ty. A sep a rate branch
circuit is rec om mend ed, sized ac cord ing to the National Elec-
tri cal Code for the current shown on the pump name plate.
3. All plumbing (discharge and vent lines) must be in stalled to
meet local codes. Unit must be vented. DO NOT USE AN
AU TO MAT IC PLUMBING VENT DEVICE SIM I LAR TO A
"PRO-VENT". Some states require this product to be installed
by a licensed plumb er.
4. Repair and service should be performed by an au tho rized
service station only.
5. CHECK VALVE MUST BE USED TO RE DUCE UN NEC -
ES SARY CYCLING OF PUMP. Check valve must be pur-
chased sep a rate ly.
6. Dewatering pumps are not designed or intended for han dling
raw sewage.
7. Maximum operating temperature must not exceed 77°F
(25°C).
8. For health reasons, do not unplug, turn off, or disable pump
and use pump tank system as a way to fi ll up a sink or laundry
tray, etc.
9. Unit is designed for above ground installation only.
NOTE: Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certifi ed pumps are
certifi ed to CSA Standard C22.2 No. 108.
Notice to Installer: Instructions must remain with installation.
Product information presented here re ects con di tions at time of publication. Consult factory re gard ing dis crep an cies or in con sis ten cies.
FW0107
1104
Supersedes
0704
Manufacturers of . . .
“Quality Products since 1866”
95 N. Oak St. • Kendallville, IN 46755
1-800-345-9422
MODEL:_______________________
DATE CODE: __________________
DATE INSTALLED: _____________
1. Inspect your unit. Occasionally, prod ucts are dam aged during ship ment. If the unit is damaged, contact your dealer before using.
Do Not remove the test plug from the pump.
2. Carefully read the literature provided to familiarize yourself with specifi c details regarding installation and use. These materials should
be re tained for future reference.
SEE BELOW FOR LIST OF WARNINGS
SEE BELOW FOR LIST OF CAUTIONS