Owner's manual

10
95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.
WELL TO PUMP CONNECTION (SUCTION PIPE)
3
IL1543
1 in. x 5 in. nipple
1 in. opening
3. Wrap thread tape around both ends of a 1 in.
x 5 in. nipple (not included) and thread the
nipple into the 1 in. opening in ejector. Hand
tighten, then tighten 1 turn with pipe wrench.
4
IL1544
1-1/4 in. male
PVC adapter
4. Wrap thread tape around threads of a 1-1/4 in.
male PVC adapter (not included) and thread
over long venturi tube and into ejector.
1
IL1541
1 in. Close Nipple
1-1/4 in. Foot Valve
1-1/4 in. Male x 1 in. Adapter
Deep Well Installations Only
1. Wrap both ends of a 1 in. close nipple with
thread tape. Thread the close nipple into 1-1/4
in. male x 1 in. adapter and thread the adapter
into a 1-1/4 in. foot valve (all not included).
Thread the other end of close nipple into
bottom of ejector. Hand tighten, then tighten 1
turn with a pipe wrench.
2
IL1542
Short
Long
2. IMPORTANT: For deep well applications, use
long venturi tube in ejector body. Do not use
short venturi tube in deep well applications.
NOTE: Hand-tighten only.