5. Thread a 1 in. female PVC adapter (not
included) onto the 1 in. x 5 in. nipple. Hand
tighten, then tighten 1 turn with a pipe wrench.
5
6
6. Using a two step PVC system (not included)
attach enough couplings and rigid PVC pipe
(not included) to the adapters to equal the
depth of the well minus 5 ft.
7. Before sliding the pipe assembly into the well,
firmly clamp the assembly with a pipe clamp
(not included) to prevent the assembly from
sliding down into the well.
7
8
8. Remove the pipe clamp and slide well seal
over the PVC pipes and onto the well casing.
The PVC pipe should extend approximately
12 in. from the well seal, depending on the
height of the pump.
NOTE: Do not let assembly slide down into well.
Tighten the well seal until rubber gaskets are tight
against the well casing and the PVC pipes.
IL1545
1 in. female
PVC adapter
1 in. x 5 in.
nipple
IL1546
Pipe clamp
40 ft.
maximum
Water level
5 ft.
minimum
12 in.
PVC Pipes
Well Seal
Well Casing
WELL TO PUMP CONNECTION (SUCTION PIPE)