Owner's manual

13
95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.
1
1 in. Discharge Tee
1. Wrap thread tape (not included) around
threads of a 1 in. discharge tee (not included).
Using a pipe wrench, thread the 1 in.
discharge tee into the top of pump.
NOTE: To improve performance and consistency,
a flow control (not included) is recommended
for deep well applications in place of a standard
discharge tee. This will help regulate water
pressure fluctuations and may prevent loss of
prime.
PUMP TO TANK CONNECTION (DISCHARGE PIPE)
2. Connect a 1 in. MPT x 1/4 in. FPT galvanized
bushing and pressure gauge (both not
included) or a pipe plug (not included) to the
discharge tee. Do not tighten, as you will
prime pump later at this location.
Pressure gauge
or pipe plug with
bushing
Discharge Tee
2
3. Wrap thread tape around the threads of a
1 in. male PVC adapter (not included) and
thread the adapter into the discharge tee.
4. Continue with ttings and pipe to the
pressure tank. A 1 in. union is optional but
recommended for easy connection and
disconnection.
1 in. male
PVC adapter
Discharge
tee
3
1 in. union
To pressure
tank
4