TANK TO HOUSE CONNECTION
5. Attach the pipe from the pump to the tee
installed in Step 4. Then, from the tee,
install 3/4 in. pipe and optional shut off
valve (not included) to connect tee to
house plumbing.
IL1369
Glue
To House
Plumbing
From Pump
Shut off valve
5
PUMP ELECTRICAL CONNECTIONS
WIRE SIZE CHART
Distance
from Motor to
Meter
Recommended Copper Wire
and Fuse Sizes
Single Phase Motors
1/2 HP 3/4 HP 1 HP
115
Volt
230
Volt
115
Volt
230
Volt
115
Volt
230
Volt
0-50 Ft.
50-100 Ft.
100-150 Ft.
150-200 Ft.
200-300 Ft.
14
12
12
12
10
14
14
14
14
14
14
12
10
10
8
14
14
12
12
10
12
12
10
8
6
14
14
12
12
10
Fuse Size
(Amps)
15 15 15 15 20 15
WARNING:
Always disconnect pump from electricity before
performing any work on the motor.
Under-sized wiring can cause motor failure and even
re. Use proper wire size specied in the Wire Size
Chart.
Replace damaged or worn wiring cord immediately.
Do not kink power cable and never allow the cable
to come in contact with oil, grease, hot surfaces, or
chemicals.
The pump must be properly grounded using the proper
wire cable with ground.
CAUTION:
Protect the power cable from coming in contact with
sharp objects.
All wiring should be performed by a qualied electrician in accordance with the National
Electric Code and local electric codes.
Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Refer to the
Wire Size Chart for proper fuse size.
6. IMPORTANT: Air pressure in the tank
must be 2 PSI lower than the “cut-in” of
the pressure switch. Pump has a 20/40
PSI pressure switch, so tank pressure
must be set at 18 PSI. Locate the air
valve/stem on the tank and check
pressure with a tire gauge (not included).
If air needs to be removed, press down on
valve to bleed off air. Use a tire pump or
air compressor to add air if needed.
Tire gauge
Tank
Air Valve/Stem
6