WATER SOFTENER TROUBLE SHOOTING
JUST INSTALLED UNIT AND WATER IS NOT SOFT
WHAT TO CHECK HOW TO CORRECT
Has unit been properly installed Re-read instructions to see that all steps were followed
By-pass in plumbing On a 3-way by-pass valve system, open valves on pip-
ing coming into and out of softener. The valve in between
MUST be closed and in good condition. Most units include
a by-pass valve which is connected to the control valve.
Make certain that it is in the service position.
Is unit piped in backwards Check arrows where pipe threads into valve head and make
sure water is owing consistent with the direction arrows
are pointing.
Hot water tank hardness Allow sufcient time for hardness that has built up in your
water heater and pipes to run through system. Repeated
ushing of the water heater tank can also be done.
Is there resin in tank Softeners ship with resin already in the tank. Make sure the
resin has not been emptied or dumped. Put a trouble light
behind resin tank and you should be able to see the resin
thru the mineral tank. The tank should be approx. 2/3 full.
Valve head is not working correctly and causing water ow
not to go through softener
Shut off water supply, de-pressurize the unit*, unscrew the
valve head from unit and exchange it.
Softener has been undersized and does not effectively re-
move the amount of hardness in your water
Draw a sample of untreated water before it goes through
the softener and a sample of treated water after the soft-
ener. Have the samples analyzed to see if any hardness is
being removed.
Water ow rate going through the softener is not allowing
time for the unit to soften
Open an outside faucet and ll a measured bucket up with
water for 1 minute. The amount of gallons in the bucket tells
you how many gallons per minute are being run through
the softener. Call 1-800-545-2206 to see what the GPM limit
is on the specic unit you have purchased. Add a ow con-
trol accessory to your unit if needed.
*To depressurize the unit, refer to valve instructions for your particular unit.
WATER TASTES SALTY OR BRINE TANK FILLS WITH WATER
WHAT TO CHECK HOW TO CORRECT
Is backwash water owing freely down to drain with an air
gap and no back siphoning
Put valve into “Backwash” position and follow water ow
down to drain. If over 20 ft., use 3/4” (or larger) drain tub-
ing. Drain line should be no more than 8 ft. lift.
Brine salt tube and connections not allowing salt solution
into mineral tank to regenerate
Visually check tubing for cracks or kinks. Check ttings for
proper assembly and tightness as diagrammed.
Brass
Compression
Nut
Brass
Insert
Plastic
Ferrule
Poly
Tubing
IL0707
Injector or injector screen plugged Put softener in by-pass position and de-pressurize the unit
by putting into “Backwash” position. There will be 2 screws
on neck of valve where the salt rinse line goes into softener.
Remove the 2 screws and clean screen and remove any