Port to 4 Port 10/100Mbps VDSL2 Ethernet Extender Kit over Single Pair Wire – 1 km 410VDSLEXT2 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com IT: Guida per l'uso - it.startech.com NL: Gebruiksaanwijzing - nl.startech.com PT: Guia do usuário - pt.startech.com For the most up-to-date information, please visit: www.startech.
FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Table of Contents Introduction.............................................................................................1 Packaging Contents.................................................................................................................................. 1 System Requirements............................................................................................................................... 1 Product Overview......................................................................
Instruction Manual ii
Introduction Packaging Contents • 1x 1 Port VDSL2 Ethernet Transmitter • 1x 4 Port VDSL2 Ethernet Receiver • 2x Universal Power Adapters (NA/UK/EU) • 1x RJ45 to VDSL2 Cable • 1x RJ11 Cables • 1x Instruction CD • 1x Instruction Manual System Requirements • 10/100 Mbps Ethernet Network • Available AC electrical outlets • RJ11 Cable or RJ11 lines in building infrastructure Instruction Manual 1
Product Overview Front / Side View Transmitter Unit DC Input Receiver Unit LED Indicators Rear View RJ45 Port LED Indicators DIP Switch RJ11/RJ45 VDSL Line Port Transmitter Unit Receiver Unit DC Input Instruction Manual Reset RJ11 VDSL Line Port RJ45 Ports 2
LED Displays Transmitter Unit LAN LED Display LED 1 Blinking ON Activity OFF Link up Link down 2 100 Mbps 10 Mbps 3 Full duplex Half duplex VDSL LED Display LED 1 Blinking OFF Activity Device Power On Device Power Off - CPE Mode CO Mode Linked Offline 2 3 ON Slowly: Idle Quickly: Training Receiver Unit LED Blinking ON PWR SYS OFF Device Power On System Activated System Running CO CO Mode On CPE CPE Mode On Activity LINK Slowly: Start Connection Linked Quickly: Data T
Installation Hardware Installation Transmitter Unit 1. Connect the provided power adapter from an AC electrical outlet to the DC Input on the Transmitter Unit. The “PWR” LED should light up solid. 2. Set all four of the DIP switches to the upward (OFF) position. This places the unit in CO mode. 3. Connect an RJ45 Ethernet cable to the RJ45 LAN Port on the Transmitter Unit. 4. Connect the other end of the Ethernet cable into your Ethernet network device (eg: switch, Ethernet modem). 5.
DIP Switch Settings - Transmitter The Transmitter Unit has a 4-position DIP switch for configuration of Side, Channel, Rate Limit, and SNR. For initial setup, DIP switch 1 is usually set to the upward (OFF) position, ensuring the unit is set to CO mode (Receiver Unit set to CPE mode by default). When using the 410VDSLEXT2, one end (Transmitter or Receiver) must always be set to “CO” mode, while the opposite end must always be set to “CPE” mode.
OFF: If Pin 2 is in the OFF position, the Transmitter Unit will operate in Interleave mode, with communication protection for up to 250ms of impulse noise with latency less than 6 ms ON: If Pin 2 is in the ON position, the Transmitter Unit will operate in Fast mode, with direct data transmissions having less than 1ms of latency. Pin 3 - Band Plan OFF: If Pin 3 is in the OFF position, the Transmitter Unit will operate in Symmetric mode, with both downstream and upstream transmissions operating on the G.
Configuration Web Interface The Receiver Unit has a built-in web interface for configuring the settings. There is no software installation required. To access the Web Interface, open a web browser (Internet Explorer, Chrome, Firefox, etc.), and navigate to “http://192.168.1.1” Note: If you had previously changed the IP address, login to the modified IP address. You will then see a login page. Login to the system with your user name and password.
System Authentication Configuration Change your login name and password in this area. Press the “Update” button to save your changes. System IP Configuration Set your IP configuration settings, including IP address, subnet mask and gateway. System Status Review hardware and software information and update device description in the “Comment” field if desired.
Load Default Setting Provides two methods to restore the 410VDSLEXT2 to default settings. 1. Reserved IP: Allows you to reload the default factory settings without changing your IP address. 2. All: All settings will be restored to the original default settings, including IP address. Once you choose a method, press the “Load” button to activate. Reset Device Restarts the 410VDSLEXT2. Click on “Confirm” to restart.
Configuration Backup/ Restore To create a backup of your settings, click the “Download” button and a pop-up will display, letting you choose a location to save a backup file. To recovery a backup, click the “Choose File” button and choose which file to restore from. Enter your password and click on the “Update” button to start the restore process.
Port Management Port Configuration Set port configurations and select which ports to apply these settings to. Select all four ports to apply each port with the same settings. Press the “Submit” button to apply the new settings. All information will be updated in the displayed status table. Flow Control Setting Choose to Enable or Disable “Backpressure” and/or “IEEE 802.3x Flow Control”. Click the “Submit” button to save your settings.
Port Mirroring Choose to mirror configurations using two settings, click on “Change Mirror Mode” button to change your mirror setup style. In order to use the port mirroring function, you will need the following information: 1. Mirror Port: Select a mirror port to monitor the traffic source. 2. Mirror Mode: Modes 1 and 2 • Disable: Port mirroring function is disabled. • Rx: Copy the incoming packets of the selected source port to the selected mirror port.
Bandwidth Control Set bandwidth control on individual ports. Select the port that you wish to control, and then enter the Tx and Rx rates. Click on the “Update” button to save the settings you’ve entered, or click on the “Load Default” button to restore settings to the default value for the selected port. Once settings are saved, the table will show the current values set up for each port. Broadcast Storm Control This section lets you block excessive broadcast packets.
CRC Counter Displays the number of CRC errors while the 410VDSLEXT2 is active. Click the “Clear” button to reset the counter and the “Refresh” button to update the latest counter information. VLAN The 410VDSLEXT2 provides two options for VLAN setup. By “Port Base” or by “Tag Base.” If you choose to set up VLAN based on Port, the settings in Tag Base will not be activated. Port Base VLAN Ensure your “VLAN Mode” is correct. If incorrect, click the “Change Mode” button to switch VLAN mode.
Tag Base VLAN Select “Tag Base” from the “VLAN Mode” using the “Change Mode” button as need. In Setup Area 1, you can choose the VLAN number, and which port you want to add or remove a tag. In addition, you can check all the VLAN members you wish to have in this VLAN number. Click on the “Submit” button to save your changes.
QoS Setting Priority Classification Enable QoS function based on the selected priority mode. If you need to start QoS function, please make sure you visit this page first and enable the priority mode you wish to apply; otherwise, the QoS function will not be activated. Queue Scheduling Mode There are two modes in “Queue Scheduling Mode”: 1. Strictly Priority: Services the queues based on priority only. As traffic comes into the modem, traffic on the highest priority queue, Q3 is transmitted first.
Port-Based Priority Two items should be selected in order to set this priority up. 1. Port number: Choose the port number you wish to apply this policy. 2. Queue number: Choose which queue you wish the selected port to belong to. VLAN Tag Priority You can assign VLAN priority and its corresponding queue number in this section.
TOS/DSCP Priority You can assign a queue with a DSCP priority. Click on the “Submit” button and the information will be saved and updated to the table below. Note: In order to allow QoS running TOS/DSCP priority, make sure you change the “Priority Classification” option to “TOS/DSCP Priority” first. TCP/UDP Priority First, choose the “Logical Port Type” and press the “Submit” button to start this function.
Security Filter MAC ID Filter Five MAC addresses can be stored in the “MAC ID Filter”. Choose which entry number you wish to save the MAC and enter the MAC address in the “MAC Address setting” field, as well as its mode. The below table is then updated to display the MAC address you just saved. If you wish to remove all the MAC addresses in the table, click on the “Clear All” button to remove every address.
Specific IP Address: Choose which entry you wish to add this set of data. In this mode, you need to provide specific IP addresses. Click “Submit” once you finish your modification. IP Address Range: Click on the “Change to Range Mode” button to switch edit sections. Then set a range of IP addresses by entering the “start” IP address and the “end” IP address. VDSL Setting Port Setting In this section, you can change VDSL port settings.
Mode Select In this section, you must set the Receiver to CO (Central Office), or CPE (Customer Premises Equipment) operating modes. Select the Receiver mode, and once selected, click the “Submit” button to save the changes. When using the 410VDSLEXT2, one end (Transmitter or Receiver) must always be set to “CO” mode, while the opposite end must always be set to “CPE” mode. Setting each unit to CO or CPE mode is usually based on which direction you want the most bandwidth delivered.
Connector Architecture Ethernet Ports The RJ45 Ethernet Port interface is an 8-pin modular jack. The table below displays the pinout assignments. Pin Number Assignment (MDI-X) 1 RX+; Receive data + 2 RX-; Receive data - 3 TX+; Transmit data + 4 Not used 5 Not used 6 TX-; Transmit Data - 7 Not used 8 Not used VDSL Ports The VDSL Port is standard 8-pin modular jack. The table below displays the pinout assignments.
Resetting Your Device There is a reset button on the rear of the 410VDSLESXT2 Receiver Unit. Please use a narrow item such as a pencil or paper clip, and gently press the Reset Button for several seconds. This will reset all the configurations and you can login to the web interface using the default IP address, ID, and Password. Note: 1. Press the button for 2 seconds: Reboots the 410VDSLEXT2 without resetting any configuration settings. 2.
Instruction Manual 24
Technical Support StarTech.com’s lifetime technical support is an integral part of our commitment to provide industry-leading solutions. If you ever need help with your product, visit www.startech.com/support and access our comprehensive selection of online tools, documentation, and downloads. For the latest drivers/software, please visit www.startech.com/downloads Warranty Information This product is backed by a two year warranty. In addition, StarTech.
Instruction Manual 26
Hard-to-find made easy. At StarTech.com, that isn’t a slogan. It’s a promise. StarTech.com is your one-stop source for every connectivity part you need. From the latest technology to legacy products — and all the parts that bridge the old and new — we can help you find the parts that connect your solutions. We make it easy to locate the parts, and we quickly deliver them wherever they need to go. Just talk to one of our tech advisors or visit our website.