User's Manual

100171-03 Water Meter Interface
Final Assembly Procedures 8000171-60-01
March 11, 2003 Page 2
© Copyright 2003,
StatSignal
Systems, Inc.
All Rights Reserved
* * C O N F I D E N T A L * *
(222051)
k. 1 each 3ft. long 22/3-AWG wire asby. (222056)
l. 1 each paper tie (999110)
4.2 Tools
The following tools are required to enable completion
of the installation process:
a) 1 Phillips Head screwdriver
b) Wire Strippers/cutter
c) 1 Drill with a 1/2” bit
5. PROCEDURES
5.1 Preparation
Prior to beginning the following procedures, the
operator must make sure he/she is grounded to avoid
electrostatic discharge.
5.2 22 AWG 3.5” Red/Black Wire Assembly (222051)
1) Assemble a Molex connector (222058) with one 3.5”
Red 22 AWG wire and one 3.5” Black 22 AWG wire to
complete the 222051 wire assembly
5.3 22/3 AWG 3ft Wire Assembly (222056)
1) Assemble a Molex connector (222058) with one 3 ft
22/3 AWG wire.
2) On the opposite side from the Molex connector
(222058) strip 1.5” of the outer jacket,
a. Strip 1/8” of the red and black inner wires,
b. Cut the green inner wire.
5.4 Battery Assembly (171500)
1) Solder the 22 AWG 3.5” long red wire of the 222051
wire assembly to the positive side of the battery
(362001)
2) Solder the 22 AWG 3.5” long black wire of the
222051 wire assembly to the negative side of the
battery (362001)
5.5 Lid Assembly (171501)