- 9 -
Attention: Keep the steam engine clean.
Attention: To avoid damage to the equipment, do not connect strong electrical current directly to the components.
IMPORTANT: Each unit shall be provided with a pressure-release device to address overpressure due to inadvertent blockage of the output
steam head or piping. If factory installed, it shall be provided with no more than 6 inches (150mm) of piping between the device and the
generator tank. If shipped with the steam generator, the installation instructions shall indicate it shall be installed to the generator tank with no
more than 6 inches (150 mm) of piping.
535mm
435mm
Steam outlet
Safety valve
Water inlet
Water
drainage
Fuse for wire power supply
Power wire hole
Con t ro l le r wi re
and light wire hole
350mm
385mm
234mm
273mm
183mm
34mm
Fuse for wire
power supply