Electrical requirements:
Electricity supply circuitry:
1. Test the voltage of the electric supply and make sure that the steam engine with suitable electric voltage is used.
2. Insulated copper wire should be used with a heat resistant temperature of 194oF and a specified voltage of 500V. Refer to national
or local electricity consumption code for the specifications. Refer to the ammeter for the ampere.
3. Choose steam engine with suitable item number, and plug the ground wire into the ground terminal.
4. Install an independent GFCI circuit breaker between the power supply and the steam engine so as to provide an electric supply
with overflow protection and electricity leakage protection.
Important: All the connections must be in accordance with national and local electricity code and be installed by professional electricians.
Ampere Meter
Type
Applicable space of the
room (m
3
)
Electricity supply
Max. Electrical
current (A)
Specifications for power
wire ( A W G)
GS08-6kW
5~8
220-240V / (1PH/2PH)
27.3A
10# or 6.0mm
2
208V / (3PH)
16.7A
12# or 4.0mm
2
380-415V / (3PH)
9A
12# or 2.0mm
2
GS08-9kW
10~12
220-240V / (1PH/2PH)
41A
8# or 8.0mm
2
208V / (3PH)
25A
12# or 4.0mm
2
380-415V / (3PH)
13.7A
12# or 2.0mm
2
GS08-12kW
14~16
220-240V / (1PH/2PH)
55A
6# or 10.0mm
2
208V / (3PH)
33.3A
8# or 6.0mm
2
380-415V / (3PH)
18.2A
12# or 4.0mm
2
The data provided above are for 220-240V (1PH/2PH) and 208V (3PH) and 380-415V (3PH).