Temperature detector installation
1. The position of the temperature sensor should be within 4-5ft above the ground. Try to avoid installing near the steam mouth or the
opening side of the steam room door.
2. As shown in Fig.1, drill a small hole (10mm) in the selected position.
3. Apply silicone along the edge of the back of the detector foundation (as shown in Fig.2).
4. Use a locknut to lock the detector foundation. (As shown in Fig.2)
5. Push the temperature detector go through the back of the detector foundation (As shown in Fig.3)
6. The temperature detector should be installed by extending about 1cm from the front of the room for accurate temperature.
7. Apply silicone to the back and set the detector. (As shown in Fig.3)
Controller Panel illustration
1
2
3
4
5
6
Steam Indicator LED
LED SCREEN
Mood Light ON/OFF
7
8
9
Power ON/OFF
Power Indicator LED
Water drain Key
Locknut for temperature
detector foundation
Drill
10
1cm
Ground
1.2~1.5m
(Fig.1)
(Fig.2) (Fig.3)
Temperature detector