Instructions / Assembly
- 5 -
Attention: The steam generator (including the controller) are UL approved.
Installation drawing of the steam generator
Installation of pipeline
Attention: The installation of all the pipes should be completed by qualified plumbers or technicians.
1. Use brass or copper pipes only.
2. Do not use black, galvanized or PVC pipes.
Water supply pipe (1/2'')
1. Connect cold water pipe to water inlet.
2. Install shutoff valve in the water supply pipe. The shutoff valve should be installed in a place where it is easily operated in case of
emergency.
3. Clean the water supply pipe completely before connecting it to the steam engine.
4. It is suggested that a water filter should be installed in the water supply pipe.
5. The water pressure should be no less than 20 pounds/square inch (psi), and no more than 75 (psi). If necessary, decrease or
increase the pressure accordingly.
S team g e n era to r
W ate r D rain Valv e
W ate r In let P ip e
S team
o u tlet
p ip e
C o n tr o l p an el
S u p p l y
S tea m O u tle t
P ress u r e relie f v alv e
!
A t t e n t i o n :
T h e d r a w i n g i s o n l y
f o r e x p l a n a t i o n .
F o r p r a c t i c a l d e s i g n o f s t e a m
r o o m , p l e a s e c o n s u l t w i t h
q u a l i f i e d d e s i g n e r , a r c h i t e c t
o r b u i l d e r .