Instructions / Assembly

- 6 -
Steam pipe (3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'')
1. Do not install any valves in the steam pipes. The steam can never be obstructed.
2. Install a brass or copper steam pipe(3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'') as connector between the steam outlet and the
steam nozzle.
3. The heat insulation material used to insulate the steam pipe should be resistant to temperature as high as 248oF or higher.
4. Do not bend the pipe so that the cooled water will not stay in the curve of the steam pipe.
5. The shorter the steam pipe, the better. Try to decrease the number of elbows and avoid abrupt turns.
6. Have no valleys or dips in the output steam line.
7. Do not install a valve in the steam line.
8. Do not connect the drain valve into the steam line.
9. Do not connect the over-pressure device output into the steam line.
Steam nozzle (3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'')
Attention: In order to protect the steam nozzle, do not use any tools to tighten that will scratch finish, use a little soap water and soft sponge
to wipe, and do not use erosive chemical solutions or abrasive cleaning tools.
WARNING!
The steam nozzle and steam outlet are very hot! Avoid installing the steam nozzle near steam bathers.
1. Install the steam nozzle 6-12 inches above the ground. If the steam bath is in the bathtub or
bathroom, install the steam nozzle 6 inches above the bathtub.
2. The steam spray outlet should be installed face down. Wrap a few circles Teflon tape around the
threads of the steam pipe, install the steam nozzle and tighten with hands.
DANGER!
1. Installer la tête d’injection de vapeur enter 15 et 30 cm au-dessus du sol. Si le bain de vapeur se
trouve dans la baignoire ou la salle de bains, installer la tête d’injection de vapeur à 15 cm au-
dessus de la baignoire
2. Le jet de vapeur doit être dirigé vers le bas. Entourer le filet du tuyau de vapeur de quelques
couches de Teflon, visser la tête d’injection de vapeur et visser manuellement