Steam Planet Superior Encore Steam Generator Installation & Operation Manual (6kW, 9kW, 12kW, 18kW & 24kW) Rev 6/2022
Table of Contents Safety Notes ............................................................................................................................................................................ 3 Warnings ................................................................................................................................................................................. 3 Choose your size of machine .........................................................................................
Safety Notes • • • • • • • • • is a safety warning symbol and it should be observed strictly. Failure to do so may cause bodily injury and financial loss. The power supply must be installed according to the local standard and with GFCI (Ground Fault Current Interrupter.) Test the GFCI before using to confirm its security and validity. The grounding for electrical appliance should be connected to a permanent ground.
Choose your size of machine Measure the length, width, and height in feet of the current steam shower or bathtub room. Example; L:7 x W:5 x H:8 = 280 Cubic feet x 2 to get complete cubic measurement Note: Multiplying the cubic feet by two is done to account for heat loss due to the room having natural stone such as granite or marble, exterior walls, ceiling height exceeding 8 feet, ceramic tile, or glass walls. Refer to the Parameter section to know if you have the correct size needed for your space.
Parts List Standard Package Steam Generator Main power box Keypad with attached 11ft power cable External temperature sensor External temperature sensor foundation 12ft power box extension cable 9.
Wiring Diagram
Wiring Introduction The system consists of power box (GH21-PB), control keypad (GH21EE), Bluetooth module GH21-BT and steam generator (GS08-HW). Power box (GH21-PB) provides 14v DC and there are 6 power output with DC5521 connectors. The input voltage is 110V-265V and output is 50W. Control module (GH21EE) has two connectors: 14V input voltage with DC5521 connectors and temp sensor input with 2core SIM2.54 connector.
Choosing the proper location 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. Recommended locations for proper installation: The steam box should not be located further than 15 feet away from the steam room. The steam generator should not be installed inside the steam room. The steam generator should not be installed outdoors or in any place that will influence the security of the machine. Do not install it in any places where the water might freeze.
Keypad Introduction
Dual Keypad Setup When installing one inside and one outside of the shower: since both keypads have built in temperature sensors, they need to be reset. 1. Rotate the dial so the Temperature Icon is highlighted on the keypad, the current temperature will be displayed. 2. Press and hold the dial in, the steam room temperature will be displayed and the thermometer in the display will start to blink. 3.
Common Installation Problems Is the unit connected to 220V? The unit has no neutral wire, just L1, L2 and ground. To properly test for the 220V, you must test the L1 and L2 wires together and you should get 220V. If you test individually, you will get a false reading. Power box issues? Make sure the wiring that connects the power box to the keypad and steam generator is not damaged. Suggested Steam Room Layout Installation A B 10 7/16in (264.5mm) 19 11/16in (500mm) 1.
2. Connect the steam generator according to the drawing. a. b. c. d. e. Water inlet: G1/2 thread connector. Drain: G1/2 thread connector. Must be copper for at least first 3ft from the generator. Steam outlet: G3/4 thread connector Steam line: Must use copper. Insulate the line with high temp 212 plus temp rating insulation. Install a brass union on the steam line for easy disassembly.
3. Keypad and steam outlet are installed according to the drawing below. Steam generator must be installed out of the steam enclosure. The keypad can be installed according to the situation on site. Drill ɸ20 hole for wire. Tear the sticker off keypad and stick it on the wall. ▪ When using the internal temperature sensor of the keypad: • The keypad should be placed shoulder high when occupant will be sitting.
Circuit Diagram for 6kW & 9kW
Circuit Diagram for 12kW
Maintenance The unit will drain automatically 20 minutes after use. Clean the steam generator every 60 uses, and 30 if on well water. 1. Wait for the completion of automatic water discharge after each use of the steam engine to make sure the water in the tank is discharged completely before cutting off power supply. 2. There should not be any leaking or damage to the steam engine, steam nozzle, components and pipes. They should be checked monthly. 3.