Installation Guide
Wiring Introduction 
The system consists of power box (GH21-PB), control keypad (GH21EE), Bluetooth module GH21-BT and steam 
generator (GS08-HW). 
Power box (GH21-PB) provides 14v DC and there are 6 power output with DC5521 connectors.  The input voltage is 
110V-265V and output is 50W. 
Control module (GH21EE) has two connectors: 14V input voltage with DC5521 connectors and temp sensor input with 2-
core SIM2.54 connector. 
Bluetooth module (GH21-BT) has 3 connectors: 14V input voltage with DC connector: Chroma lights (20W, 12V) with 4-
pin SIM2.54 connector and 2 speaker cable with 2 wire 2-pin SIM2.54 connectors. 
Steam generator (GH08-HW) has two connectors: 14V input power with DC5521 connector and white light (20W, 12V) 
with 2-pin SIM2.54 connector. 
Module Introduction 
The system consists of power box (GH21-PB), control module (GH21EE), Bluetooth module (GH21-BT) and steam module 
GS08-HW. Power box (GH21-PB) provides 14v DC. 
The keypad controls the system and there are two temp sensor connectors: internal temp sensor and external sensor. 
When the external sensor is connected, the internal sensor will not work. 
Then using the internal temperature probe, there will be 30 to 60 second delay. 
Steam generator: controls steam function, water filling and draining. 
Reset Introduction 
Removing or adding of any modules, the steam generator will not work properly, unless power box is unplugged before 
any changes and reconnected after the change. 
Wiring: 
The power module provides 14V DC and there are 6 connectors. If the wire isn’t long enough, user can extend it 
with extension wire. All modules should be connected to the power module. 