Installation Guide

3
NOTICE TO INSTALLERS
1. The overall height from the ground to the ceiling has to be minimum of 85in for the enclosure.
2. The water pressure has to be more than 55-75 psi and, if the pressure is lower than required, you may install a booster to the
water supply.
3. Please use a 20-amp 220V GFI breaker for the electrical connection.
4. We advised to have an access panel installed on the side of the electrical/water connections for maintenance and service.
5. In the parts box is a roll of a foam type tape with one side that has an adhesive on it. This should be placed in the bottom
channels of the base where the glass panels rest.
Manufacturer reserves the right to change specs or features at any time. Please check to confirm details. 1-866-783-2661
PACKING NOTE
1. When first opening the boxes, please make sure everything is in good condition, especially if any visible damage has been
done to the package, please contact Steam Planet immediately with photographic documentation of the damage.
2. Make sure all water and electrical components are up to local and national standards.
3. Two installers are required for these units.
4. Here are the tools you may need for installation:
ASSEMBLED PRODUCT DIAGRAM
M6027/28 Right Illustrated