Installation Instructions

12 | P a g e
Rev 02/2015
HANDLE ASSEMBLY
TRIM FLANGE ATTACHMENT
Position Flange (A) on the Valve (B) with drain hole (C) at the
bottom. Place Protective Washer (D) on the short end of the
reversible Retainer Sleeve (E). Screw Retainer Sleeve (E) onto
threaded section of the Stem and Bonnet (G). Tighten Retainer
Sleeve (E) by hand until Flange (A) is snug to finished wall
surface. If the short end of the Retainer Sleeve (E) is too short,
reverse it to use the longer end.
HANDLE ATTACHMENT
Screw Stem Extender (A) onto the Valve Stem (B). Thread the
Set Screw (C) into the Handle and thread it in only three or four
turns. With valve in CLOSED position, place handle (D) onto the
Steam Extender (A) and tighten the Set Screw (C) by using the
Hex Wrench (E) that is provided.
Make sure Set Screw (C) is securely tighten to handle (D).
TEMPERATURE ADJUSTMENTS
Adjustment gear (A) is factory-set to prevent stem from reaching
full hot position. To adjust stem rotation: remove adjustment gear
(A). Rotated steam (B) counterclockwise to determine a maximum
desired temperature. Replace gear aligning adjustment stop (C)
to stem tab surface (D) to stem (B) cannot move beyond
adjustment point.