Contemporary Steam Rooms Models: M6027 & M6028 Installation & Operation Manual iN RIGHT HAND UNIT PICTURED In order to operate and use the product properly, please follow all instructions provided in this User’s Manual. Our company reserves the right to change the Manual at any time. The manual takes effect the date it’s published. This manual shall prevail if there is any difference between this and previous documents and manuals.
Table of Contents NOTICE TO INSTALLERS ........................................................................................................................................................... 3 PACKING NOTE ........................................................................................................................................................................ 3 ASSEMBLED PRODUCT DIAGRAM .........................................................................................................
NOTICE TO INSTALLERS 1. The overall height from the ground to the ceiling has to be minimum of 85in for the enclosure. 2. The water pressure has to be more than 55-75 psi and, if the pressure is lower than required, you may install a booster to the water supply. 3. Please use a 20-amp 220V GFI breaker for the electrical connection. 4. We advised to have an access panel installed on the side of the electrical/water connections for maintenance and service. 5.
PRODUCT FEATURES ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ Two-person Steam and Shower Enclosure Low Threshold 2.75″ H Base included 3.5kW Quick heating Self-Draining Steam Generator w/Steam Aromatherapy Cup 8 Body Massage Jets Hand-held Shower w/ Various water massage settings & adjustable height bracket 8 in.
PARTS LIST 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17.
INSTALLATION INSTRUCTIONS Note: Confirm the drain setup. When installing, make sure each panel is level, plump & 90-degree before securing completely. 1. Place shower tray in the corner where it will be permanently 6. Install angle brackets to the glass panel (C). Install the angle located. Note: The handing (R/L) of your unit determines bracket to the holes on glass, panel C. Refer to picture below.
9. Install angle brackets over the installation holes of glass A, connect with connector bolts (make the connection snug, but loose enough to make adjustments.) 12. Place glass D (top) on the top of the unit, align connecting holes with glass D to glass panels A, B, and C. Use connector bolt to connect. Please refer to illustration below. 10. Place bottom edge of glass A into the slot on the base as shown. A small amount of soap or lubricant on the gaskets will help with installation. 13.
15. Attach glass panel E which has a black stripe across the top and side to glass panel D and A. Note: On the front panel E there is a “notch” on the bottom. It is imperative the notch be moved as far as the base will allow; this should give you an overhang of the side panel over the base about 1/8 to 3/16 in. If you do not have the glass positioned with the overhang there will not be enough space between the door and the side panel to enable the magnetic strips to make proper contact. 17.
Door Installation Help When assembling the MA 60XX series units, the door can sometimes be the most challenging aspect of this unit. Following these few tips can make the installation much easier. First note, on one or two (depending on the model) of the glass panels is a “notch” on the bottom. It is imperative the notch be moved as far as the base will allow; this should give you an overhang of the side panel over the base about 1/8 to 3/16 in.
PFISTER HANDLE ASSEMBLY TEMPERATURE ADJUSTMENTS TRIM FLANGE ATTACHMENT Position Flange (A) on the Valve (B) with drain hole (C) at the bottom. Place Protective Washer (D) on the short end of the reversible Retainer Sleeve (E). Screw Retainer Sleeve (E) onto threaded section of the Stem and Bonnet (G). Tighten Retainer Sleeve (E) by hand until Flange (A) is snug to finished wall surface. If the short end of the Retainer Sleeve (E) is too short, reverse it to use the longer end.
MAINTENANCE & CARE Clean the cartridge assembly (D). check to ensure the two oval O-Rings (F) on the back of the cartridge (E) are in place. Disassembly: Reassemble cartridge, stem and bonnet assembly and handle. 1. Replacement parts may be available at Lowes or Home Depot. Turn on the water and test. Of the unit still leaks, replace the 2. When replacement parts are not available, please write or call cartridge (E). Price Pfister Consumer Service.
FAUCET FUNCTION AND USAGE • • • • • Water Diverter handle o Turn the diverter handle according to the signs marked on its face. When you use the hand held shower, turn the knob to the hand held shower sign; When you use the massage jets, turn the knob to the back-massage sign. When you use the rainfall shower head, turn the knob to the rainfall shower sign Cold Water and Hot: o Turn the faucet to left and right to increase/decrease the water temperature.
S198E KEYPAD USER MANUAL KeyPad Diagram 1.Crystal display 2.Power button 3.Shuttle switch 4.Volume adjust button 5.Previous 6.
KEYPAD OPERATIONS INSTRUCTIONS Press on button – Keypad will light up NOTE: When keypad has not been used for 30 seconds the locked symbol on the right side of the keypad will light up. To get out of locked mode press the Shuttle Knob If you rotate the Shuttle Knob and it doesn’t move, make sure it is not in the locked mode. Rotate the Shuttle Knob and the Various options will become highlighted on the Crystal Display (keypad).
To control the music Volume with the Keypad, Highlight the i MUSIC, PRESS the Shuttle Knob. Press the Speaker button on the bottom left of the keypad and the dB on the display will flash, rotate the Shuttle Knob to the desired volume, press the Shuttle Knob to set. While in Bluetooth mode you can receive call and talk through the microphone. If you have a waterproof phone you can make calls also. To answer incoming calls, press the shuttle knob.
ADDITIONAL INFORMATION TO EXPEDITE PARTS REQUEST Please visit homewardbath.com/support If you require additional assistance, call 866-783-2661. WARRANTY INFORMATION & REGISTRATION Please visit our website: homewardbath.com/warranty-registration Please note serial number: ____________________________ Registration must be completed within 45 days of receipt to be valid. A full description of the warranty is available on the Homeward Bath website.