Installation Guide
Table Of Contents
- READ ME FIRST
- COMMON INSTALLATION PROBLEMS:
- WARNINGS:
- MANDATORY READING
- PART 1: STEAM GENERATOR
- USER INSTRUCTIONS
- CHOOSE YOUR TYPE OF MACHINE
- MAINTENANCE
- STEAM GENERATOR CLEANING
- SENSOR PROBE REMOVAL FOR DIRECT CLEANING
- CHOOSING PROPER LOCATION
- INSTALLATION DRAWING OF THE STEAM GENERATOR
- INSTALLATION OF STEAM LINE
- BLUEPRINT FOR THE STEAM ENGINE
- ELECTRICAL REQUIREMENTS:
- AMPERE METER
- ASSEMBLY GRAPH FOR POWER WIRE
- Wiring Diagram 220-240V (1PH/2PH)
- INSTALLATION OF THE TOP LIGHT
- STEAM GENERATOR CONFIGURATION
- TROUBLE SHOOTING:
- DELUXE KEYPAD ERROR CODES
- INSTRUCTIONS FOR RESETTING THE MANUAL HI-LIMIT SWITCHES
- SPECIFICATIONS
- PART 2: STANDARD CONTROL PANEL
- PART 3: DELUXE CONTROL PANEL
- PART 4: ADDITIONAL INFORMATION
15 | Page
INSTRUCTIONS FOR RESETTING THE MANUAL HI-LIMIT SWITCHES
If the unit fills with water but does not produce steam, the issue may not be the heating element.
1. Shut off the power to the unit at the breaker.
2. Remove the top of the steam generator and make sure the power connections are tight.
3. There is an update that allows you to disconnect the wires from the terminal block and wire nut them together. This will not void the
warranty and eliminates the need for checking the tightness of the electrical connections as stated on page 4 of the manual.
4. If power connections are tight, go to the side of the steam generator where the
electrical connections are.
5. You will see a plate that is held on by 6 screws, remove that plate.
6. You will have direct view of the heating elements and the power connections.
7. Above each element is a small black plastic square. In the center of that square
is a reset button, push each one if you hear a click that was your problem. This is
a hi-limit heat protector.
8. If that does not solve the problem, unscrew the bottom wire from each element.
The elements are mounted vertically.
9. If you have a voltage tester set it to tone, touch the top element terminal with the
terminal below it.
10. You should get a buzz, if you do the element is good.
11. Do the same thing for the second element.
12. If there is no sound the element is bad and needs replacing.
SPECIFICATIONS
Important: The list below is for reference only. In actual checking and repairing, based on the national and local codes, ask
professional service personnel for advice.
Power Output
6kW
9kW
12kW
Potency Error
±10%
±10%
±10%
Duration
>1500V >1500V >1500V
Resistance (MΩ)
>20W >20W >20W
Steam Pressure
0.14MPa
0.14MPa
0.16MPa
Steam Volume (ml/min)
180 260 360
Steam Production Time
4-8 mins
4-8 mins
4-8 mins
Water Tank Volume
1.5GAL 1.5GAL 3.2GAL
Applicable space of the room (ft
3
)
140-320 320-460 460-700
Important: The parameter listed in the above table may vary from place and temperature, please consult a qualified designer or
architect for more detailed use.
NOTE: Steam Bath Generators are considered to be able to operate above atmospheric pressure in abnormal operation and shall
therefore, comply with UL clause 64.8.
12kW is
pictured.
6&9kW have
only 2 reset
buttons.