Installation Guide

19 | Page
OPERATION INSTRUCTIONS
1. When power supply is applied to the steam box system the RED stand-by light (#9) will be illuminated. (see Illustration of the
controller panel for location)
2. Pressing the ON/OFF button will start the system. The steam box will fill with water. This will take a few minutes; the water
may cycle on and off a few times as the water tank fills. This is normal operation. The display will show ambient Temperature
and Running time - 8 hrs. Both red lights will be off.
3. When the Red light next to the ON/OFF button becomes illuminated, the system is operating and will start generating steam in
4 8 minutes. If it starts to flash, it indicates a lack of water in the tank.
4. Pressing the UP and Down arrows under the temperature display will adjust the temperature accordingly. The temperature
range is 25ºC to 68ºC or 78ºF to 150ºF. The unit will cycle on and off to maintain the set temperature. See #7 for instructions
on switching between Fahrenheit and Celsius.
Once the user has adjusted the temperature to their preference, the temperature lights will blink several times and the time
and temp will be the active setting. The unit will display room temperature.
5. When system is on, press UP or DOWN triangle keys on control panel to adjust running time, meanwhile, time display window
shows the time you desire. The steam time range is 1 minute to 8 hours. When setting time to less than 1 hour, the time unit is
by the minute; when more than 1 hour, the unit is hour and time display window will indicate “8 h” (hours).
6. When system is on, press the LIGHT key to turn on lights; press again to turn off. If applicable.
7. When system is in standby mode, press DOWN temperature key and UP triangle key at the same time. This will switch
between Fahrenheit and Celsius.
Attention:
1. Use soft cloth with soap and water to clean the controller. Technical Assistance: For any information or assistance, call
866-783-2661.
2. Do not use abrasive cleaning tools.
Helpful Hints:
Steam Generator does not produce steam:
If your steam shower has been working with no issues, and one day the steam generator just doesn’t come on, make sure the time
and temperature are set (even if you have never changed it). Sometimes the unit will reset and if the time and/or the temperature
are not set, the unit will not come on.
During initial start-up, set to the maximum temperature for first time operation. Afterwards lower to preferred temperature setting.
If the unit has been operating properly and then all of a sudden water fills the tank and the steam indicator LED light goes out and there
is no steam, check the 221ºF hi-limit switch (page 15). If this occurs, there is a reset button at the center of the switch. Press the
button. Check each button that is above each heating element and that should solve the problem.
The reset button can be tripped during shipment or as a new installation. The steam indicator LED light goes out and there is no
steam, check the 221ºF hi-limit switch (page 15). If this occurs, there is a reset button at the center of the switch. Press the button.