Installation Guide

21 | Page
BLUEPRINT FOR THE CONTROL PANEL
Complete set including:
o Control panel
o Temperature sensor and holder
o User manual
o Middle cable between dual panels (6.5 feet)
INSTALLATION INSTRUCTION OF CONTROLLER
Important
Before installing the controller, make sure the steam generator is shut off otherwise the controller
may not operate properly or be damaged.
Step One:
The controller is designed to be installed in the steam room. Points to consider:
1. 4-5 feet from the ground or a convenient height.
2. Keep away from the steam nozzle and do not expose under the direct spray of steam or water.
3. Install on a wall.
4. The position of installation should facilitate easy operation and convenient wiring. The controller wire is 1.6 feet long, with
an extension wire of 20 feet long. The installation of the controller should be in a position not more than 21 feet from the
steam generator.
Important
Do not install the controller under the water pipe or in a position where the keypad is in constant contact with water.
Step Two:
Drill a round hole of 1 3/8 inches in diameter in a chosen position, no larger or smaller.
Step Three:
Attention: Do not twist the cables.
Pull the controller wire through the round hole, connect it to the extension wire and then to the steam generator and connect with
the corresponding wire in the generator. Do the same when unplugging.
Important Do NOT pull tight, fix tight or clip the controller wire in case of damage to it. Do not secure the key pad to the wall at this time.
Step Four:
Start the power supply to the steam generator, check connection, check each item on pages 23-24 to make sure all functions work.
Important
Before attaching the controller, make sure the steam generator is shut off otherwise the controller may not operate properly or become
damaged.