Installation Guide
10
Rev. 8.2018
Attention: Keep the steam engine clean.
Attention: To avoid damage to the equipment, do not connect power directly to the components.
IMPORTANT: Each unit is provided with a pressure-release device (safety valve) to address overpressure due to inadvertent blockage of the
output steam head or piping.
ELECTRICAL REQUIREMENTS:
Electricity supply circuitry:
1. Test the voltage of the electric supply and make sure that the steam engine is supplied with suitable electric power.
2. Insulated copper wire should be used with a heat-resistant temperature of 190ºF and a specified voltage of 500V. Refer to national
or local electricity code for the specifications. Refer to the ammeter for the ampere.
3. Make sure the steam engine and power supply are appropriate for each other.
4. Install an independent GFCI circuit breaker between the power supply and the steam engine.
Important: All the connections must be in accordance with national and local electricity code and be installed by professional electricians.
Note: All units are 220-240 Volts. The terminal may read N, L, G. The N is not a neutral. It is the second leg of the 220V of the power source.
AMPERE METER
Type
Applicable
space of
room (ft
3
)
Electricity supply
Electrical current
draw (Amps)
Specifications for
for power wire ( A W G)
GS08-6Kw
140-320
220-240V / (1PH/2PH)
27.3A (30 Amps)
#10 or 6mm
GS08-9kW
320-460
220-240V / (1PH/2PH)
41A (50 Amps)
#8 or 8mm
GS08-12kW
460-700
220-240V / (1PH/2PH)
55A (60 Amps)
#6 or 10mm
ASSEMBLY GRAPH FOR POWER WIRE
Attention: To avoid the damage to the equipment, do not connect power directly to components.
WARNING!
This graph is for explanation only. For actual installation, refer to national and local electric codes and consult with a professional electrician.
See Installation Update Bulletin on Page 4.