TEMPERATURE ADJUSTMENTS
Adjustment gear (A) is factory-set to prevent stem from reaching
full hot position. To adjust stem rotation: remove adjustment gear
(A). Rotated steam (B) counterclockwise to determine a
maximum desired temperature. Replace gear aligning
adjustment stop (C) to stem tab surface (D) to stem (B) cannot
move beyond adjustment point.
MAINTENANCE & CARE
Disassembly:
1. Replacement parts may be available at Lowes or Home
Depot.
2. When replacement parts are not available, please write
or call Price Pfister Consumer Service.
3. Always turn off water and release pressure before
working on your faucet.
Note: Trim Care
Cleaning instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify the warranty.
Trim products which contain porcelain or other similar substances
are not acceptable for public areas or commercial use.
Installation of said trim is at users risk!
TROUBLESHOOTING TIPS
Temperature or flow does not remain consistent.
The cartridge assembly (D) may need cleaning. Shut off water
supply. Remove handle assembly (A), unscrew retainer sleeve
(B) and remove flange (C). Remove cartridge assembly (D) and
inspect cartridge (E) and inlets for debris or sediment and flush
with water. Reassemble the whole unit and test. If problem
persist you may need to replace the cartridge.
Sleeve (B) is too short.
Extension kid 910-563 is available at a nominal charge for valves
which have been roughed-in too far back in the wall. The kit
contains a one inch stem extension, and a sleeve which is one
inch longer than the 972-300.
Dripping from either the tub spout or shower head.
Clean the cartridge assembly (D). check to ensure the two oval
O-Rings (F) on the back of the cartridge (E) are in place.
Reassemble cartridge, stem and bonnet assembly and handle.