PROBLEM POSSIBLE CAUSES SOLUTIONS
Receiving an error “E1” on the control
panel
1. The signal that transfers between
the control panel and generator has
a problem
1. Check the connection on the control
cable to make sure all 13 pins are
functional
Receiving an error “E0” on the control
panel
1. Lack of water in the tank. The water
inlet valve is not turning on which is
preventing water from entering
1. The water inlet valve is jammed or
the connecting cable is loose so
attempt to clean the water inlet valve
by switching it on and off a few
times to dislodge any buildup
2. Check the cable and make sure it is
firmly connected
3. Replace the water inlet valve
4. If the problem persists it may be
necessary to replace the PC board
The control panel shows the
temperature, but does not go on
1. The water level sensor cable or the
cable from the relay to element is
loose
2. The heating element is
malfunctioning
1. Make sure all cables to the heating
elements are well connected
2. Replace the heating element