Installation Guide

A
B
C
D
Access
Plumbing Installation Instructions
Access Requirements Models: SMP-5, SMP-7, SMP-10, SMP-12 and SMP-15
01/17
Pub. No. 232-A
- 4 -
Select a location for mounting the Steam Generator that is
accessible for installation and service. The access requirement
indicates the minimum space for convenient access to Steam
Generator.
CAUTION: All models must be installed INDOORS, in a DRY,
NON-FREEZING location away from flammable materials such
as: Gasoline, Paints, Thinners, Etc.
IMPORTANT: Steam Generator must be installed upright and level.
The serial number info should be visible and the Steam Generator
should be accessible for service.
Figure 5
Installation Suggestions
®
*Alternate Attic Location
(See CAUTION below)
*Alternate Basement Location
(See CAUTION below)
STOP
2
1
2
1
TIME
TEMP
IM
STOP
Vanity
Location
Closet
Location
*CAUTION: Steam generators must NOT be installed outdoors, in moist, humid areas, in areas prone to freezing, or
extreme heat such as an unventilated attic. To do so will void the warranty.
East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617
Access for Service Chart (See Figure 5)
Model Number
A
With AutoDrain
B
Without AutoDrain
SMP-12 and SMP-15
SMP-5, SMP-7 and SMP-10
C
D
22” 18”
22”
28” 21”
35” 28” 18”
Optional AutoDrain
Valve Model AD-900