Spec Sheet

Specications
Features
Limited lifetime warranty - 2-year in home labor warranty where
available
Generator typically can be installed up to 50 ft. from the
bathing area
Selectable "Instamist"
Proportional Steam
"Gangable" up to (4) generator
Diagnostic LED Displays
Stainless Steel Construction
Solid-State Circuitry
Codes/Standards
UL 499
UL/CUL Listed
Required Equipment
TSC Model Control
Required Electrical Service
Dedicated circuit required: See Specification Chart for proper
electrical requirements
Product Information
Water Supply - " Compression Fitting, 120 PSI Max
Steam Line - ¾" Brass NPT male thread
Pressure Relief Valve - ¾" NPT female thread
Drain Line - Capped ½" Brass NPT male thread
Generator
Weight - 50 lbs.
Installation Notes
Steam Generators can be typically mounted within 50 ft. of
the bathing area.
Steam Generators should be accessible for service.
Do NOT install near flammable material such as paints,
thinners, gasoline, etc.
Steam generators must NOT be installed outdoors, in
moist, humid areas, in areas prone to freezing, or extreme
heat such as an unventilated attic. To do so will void the
warranty.
Steamhead to be mounted 12" to18" above floor or 6"
above rim of tub and as far from the seating area as
possible.
Rough-in Notes
Access: 28" L x 20" W x 22" H (35" L with Auto Drain)
05/16
Pub. No. 275-H
Steam Generator Models: TSG-12 & TSG-15
- 1 -
Steam Generator Specication Chart
12
15
550
675
240/1/50
208/1/58
240/3/29
208/3/33
240/1/63
208/1/72
240/3/36
208/3/42
60
70
40
40
80
90
50
60
Model
Number
Product
Number
KW
Rating
* Max. Cu. Ft.
Range
Volts/Phase/
Max. Amps
Line
Fuse
17¾" x 7½" x 15½"
17¾" x 7½" x 15½"
Dimensions
L x W x H
TSG-12
TSG-15
1220
1221
1222
1223
1520
1521
1522
1523
* Refer to sizing guidelines to accurately determine the proper size generator for the installation.
90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and local
electrical codes.
®

Summary of content (2 pages)