Installation Guide

SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 31
INSTALLATION & USER GUIDE
TECHNICAL PARAMETERS
Type
4.5KW 6KW 7.5KW 9KW 10.5KW 12KW
Power (KW) 4.5 6 7.5 9 10.5 12
Voltage (V) 240 240 240 240 240 240
Current (A) 19 25 32 38 44 50
Errors Range +10% +10% +10% +10% +10% +10%
Anti-Static Constant >1500V >1500V >1500V >1500V >1500V >1500V
Insulation Resistance >20M Ω >20M Ω >20M Ω >20M Ω >20M Ω >20M Ω
Head Lamp ~12V/3W ~12V/3W ~12V/3W ~12V/3W ~12V/3W ~12V/3W
Time Set Range (min) 1-60 1-60 1-60 1-60 1-60 1-60
Steam Press (psi) 3 4 4 4 5 5
Steam Vol. (cu. in./min) 9 11 13 16 19 21
Steam Spray Time (sec) 100-180 180-240 150-210 120-180 170-230 150-160
Water Vol. (cu. in.) 80 160 160 160 330 330
Applicable Space of the
Room (cu. ft.)
90 150 225 300 400 450
IMPORTANT! The list above is for reference only. Actual checking and repairing should be based on national and local codes, ask
professional service personnel to operate.
IMPORTANT! The parameter listed above will vary by geographical location and environment. Please consult a qualified designer
and architect for more detailed use.