Installation Guide

SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 11
INSTALLATION & USER GUIDE
DRAINPIPE (1/2’’)
ACCORDING TO THE NATIONAL AND LOCAL PLUMBING CODES: The steam generator drain valve should be equipped with
a drainpipe. The steam generator drains the water by gravity.Check local code requirements for drain valves. Do not connect the
safety valve or steam line to drain line.
SAFETY VALVE (3/4’’)
1. Safety valve is an automatic system that is actuated by pressure in order to prevent steam pressure increasing in the interior
of the generator .
2. The pressure limit range of the safety valve is 15 PSIG and the pressure will begin to decrease if pressure should come over
this value.
3. If it is allowed by local codes, provide the safety valve with exterior drainpipe.
4. Do not dismantle the pressure relief valve while generator is in operation..
5. To maintain the proper automatic operation of the safety valve, make sure the safety valve connection pipe is smooth.