Full Product Manual

1. Test the voltage of the power supply
and make sure suitable voltage is used
for the steam generator.
2. or local electricity consumption code
for the pecifications. Refer to the
ammeter for the ampere.
3. Connect suitably sized equipment
grounding wire into the ground terminal.
4. All the connections must be in
accordance with national and local
electricity consumption codes and be
installed by professional electricians.
Ampere Meter
Type
Power KW
Electricity
supply (1PH)
Electricity
current(A)
Specifications for
power wire (AW G)
B-450
B-600
B-750
B-900
B-1050
B-1200
4.5
6
7.5
9
10.5
12
240V
240V
240V
240V
240V
240V
19
25
32
38
44
50
12
10
8
8
6
6
The data provided above is for 240V single-phased motors. Install an independent
circuit breaker between supply line and steam generator. Install a power disconnect
within sight of steam generator to cut-off power when not in use.
Page 9
Safety valve
Water inlet
Water
drainage
Steam outlet
Fuse for wire power supply
Power wire hole
Fuse for wire power supply
Controller wire
and light wire hole