Installation Guide

SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 27
INSTALLATION & USER GUIDE
STEAM GENERATOR MAINTENANCE
IMPORTANT! The steam generator automatically performs a water discharge operation after each use.
1. Wait for the completion of automatic water discharge after each time using the steam generator to make sure the water in the
tank is discharged completely before cutting off power supply.
2. There should not be any leakage or damage among the steam generator, steam nozzle, components and pipes. They should
be checked and repaired annually.
3. Clean the water supply pipes of the steam generator once a year.
4. Check all the faucet connections, to ensure wether they are tight and not damaged due to overheat.
5. It is recommended that the water sensor prong gets clean once every six month.
1. Remove the casing of the generator.
2. Locate the water sensor.
3. Label each electrical connections then carefully remove all connections.
4. With a wrench or a 32mm ratchet socket carefully unscrew the water senor.
5. Thoroughly clean any residue buildup accumulated on the prong.