STEAM BATH GENERATOR USER GUIDE AUTO D HI S P E R Q UI ET IN RA EA T Steam Spa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.com -IN W T UOUS S T TIN B UIL K S TA R CON UIC Q 4.5KW 6KW 7.5KW 9KW 10.
TABLE OF CONTENTS PROLOGUE........................................................................................................................3 USER INSTRUCTIONS..........................................................................................................3 CHOOSING THE RIGHT LOCATION...........................................................................................3 INSTALLATION DRAWING OF STEAM GENERATOR......................................................................
PROLOGUE Thank You for choosing SteamSpa for health, beauty and relaxation. Now you can enjoy your own private sanctuary in the comfort of your own home. Let your stress melt away as you relax in your state of the art Steam Room. For Centuries people have recognized the health benefits of saunas. Leave your stress behind and enter a world of total relaxation, ridding you of pain, toxins, and sore muscles as well as increasing your blood circulation etc., leaving your skin glowing.
INSTALLATION DRAWING OF STEAM GENERATOR Control panel Supply Pressure Relief Valve Steam Generator Water Inlet Pipe Water Drain Valve Steam Outlet ATTENTION! The drawing is only for explanation purposes. As for practical design of steam room, please consult with a qualified designer, architect or builder. Page 4 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.
Light Control panel(inside room) Control panel(outside room) The steam outlet The spare place under the wash pan £ possible location £ ATTENTION! The illustration is just an example; the practical installation must comply with the nation’s electrical criteria, and be done by a professional electrician. Page 5 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.
PLUMBING INSTALLATION WARNING! The installation of all water supply lines should be in accordance to all national and local codes by a licensed plumber. 1. Use unions when connecting pipes. 2. Use brass pipes or copper hoses only. 3. Do not use black and galvanized or PVC pipes. WATER SUPPLY PIPE (1/2’’) 1. Connect hot water or cold water pipes. The Industry recommends the use of a hot water line; However it should not exceed 160¨F. 2. Install stop valve in the water supply line.
Airproof green material belt Use airproof silica gel or corresponding airproof material to fill the gaps in the wall to achieve the water-proof and damp-proof effect. If non-heat-resistant material like acrylic is used as building material, reserve a gap no smaller than 1/4’’ and fill with heat-insulated material. Inside wall in the steam room DRAINPIPE (1/2’’) ACCORDING TO THE NATIONAL AND LOCAL PLUMBING CODES: The steam generator drain valve should be equipped with a drainpipe.
STEAM GENERATOR SPECIFICATIONS 395mm 304mm 142mm 43mm 266mm 302mm Safety valve Water inlet 32mm 188mm 151mm 206mm Steam outlet Water drainage 62mm 72mm Fuse for wire power supply C o n tr o lle r w ir e and light wire hole Power wire hole INSTALLATION & USER GUIDE Fuse for wire power supply 4.
535mm 435mm 234mm Steam outlet 34mm 35 0mm 273mm 183mm Water inlet 38 5mm Safety valve Water drainage Fuse for wire power supply Controller wire and light wire hole Power wire hole 10.5kW/12kW/15kW ATTENTION! To facilitate maintenance, keep the steam engine clean. If the information provided is limited, do not operate on the pipeline and electric equipment arbitrarily as shown in the figure for proportion. ELECTRICAL REQUIREMENTS ELECTRICAL SUPPLY CIRCUITRY 1.
Ty p e Ap p licab le s p ace o f the room (cu.Ft. *) P owe r KW El e c t ri c i t y s upply (1PH) Ele c tr ic current (A) Specifications for power wire (AWG) S450 90 4.5 240V 19 12 S600 150 6 240V 25 10 S750 225 7.5 240V 32 8 S900 300 9 240V 38 8 S1050 400 10.5 240V 44 6 S1200 450 12 240V 50 6 S1500 500 15 240V 63 6 The data provided above is for 240V single-phased motors. Install an independent circuit breaker between supply line and steam generator.
WIRING DIAGRAM S u p p ly Wa te r L e ve l Se nsor T o C ont rol P a ne l Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n ) B lack R ed S u p p ly T o C ont rol P a ne l J2 Black White Drain water valve Red Red Fill water valve B lack Red J1-2 Red Red Red Red S Black J1-1 Black Yel low R ed Black T e rm i na l B l oc k Ye l l ow / G re e n J1 B lack R ed G Black J2-1 Blac k Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n )
S u p p ly T o C ont rol P a ne l G T e rm i na l B l oc k J1 Red R ed S1200 L2 T o C ont rol P a ne l T e rmi na l B l oc k J1 INSTALLATION & USER GUIDE Red J3-2 B lack Red J2 Black White B lack Red Red Drain water valve J3-1 Black Red Red Red Fill water valve Bl ack J1-1 Black R ed Black S J2-1 Black Ye l l ow / G re e n Black Bl ack Yellow B lack R ed Red Red Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n ) Red Red Wa te r L e ve l Se nsor
STEAM GENERATOR DISSECTION DIAGRAM 2 1 14 16 3 17 15 4 13 12 6 7 11 INSTALLATION & USER GUIDE 5 10 8 9 1. 2. 3. 4. 5. 6. ENCLOSURE INSULATION BRACKET CIRCUIT BOARD STEAM OUTLET PRESSURE RELIEF VALVE WATER FILL VALVE 7. WATER DRAIN VALVE 8. SUBSIDIARY WATER TANK 9. MAIN WATER TANK 10. HEATING ELEMENT 11. 221 F HI-LIMIT 12. TRANSFORMER 13. TERMINAL BLOCK 14. FUSE 15. GROUND WIRE CONNECTOR 16. RELAY 17.
CARE & USE FOR THE CONTROL PANEL 1. Use soft cloth with a little soap water to clean the control panel. 2. Do not use crude cleaning tools. 3. If the decorating facade is damaged, contact service electrician to change it. Do not install any SteamSpa controls without reading and understanding the SteamSpa generator Installation and Instruction manual.
CONTROL PANEL INSTALLATION INSTRUCTIONS STEP ONE Determine the installation location of the control panel. The master control panel is designed to be installed in the steam room only, please install: 1. 4-5 feet from the ground. 2. Away from the steam head and do not expose under the direct spray of steam. 3. Install in the perpendicular wall. 4. The position of installation should facilitate easy operation and convenient wiring. STEP TWO Drill a round hole of 1 inch in diameter in a chosen position.
TESTING THE MACHINE 1. Make sure the power switch of the control panel is turned on (the control panel displays ---), and the water supply valve will open. 2. Press the steam switch, , the control panel will display the temperature of the environment, the steam engine begins to input water to start the steam function, and while opening the steam, press the button to open light function. 3. When there is steam output, press again, the steam will stop and the light will go off automatically. 4.
CONTROL PANEL OPERATION The control panel has a digital temperature control system which can start, stop or pause in the preset time to keep the temperature at the set number. Fig.1 ON/OFF When system is powered, all functions will still not be activated and remain in a waiting state. Digital tube will display ---- (Fig.1). In the waiting state, press the button to turn on the system and activate steam function. System will recall last use steam time and TEMP, system begins to count down.
STEAM GENERATOR MAINTENANCE IMPORTANT! The steam generator automatically performs a water discharge operation after each use. INSTALLATION & USER GUIDE 1. Wait for the completion of automatic water discharge after each time using the steam generator to make sure the water in the tank is discharged completely before cutting off power supply. 2. There should not be any leakage or damage among the steam generator, steam nozzle, components and pipes. They should be checked and repaired annually. 3.
PROBLEM POSSIBLE CAUSES SOLUTIONS The machine does not start when powered 1. Burned out fused 2. The electrical wiring became loose 3. Control panel connection loose Breakers are tripping 1. The wire connector is dampened or damaged 2. Damaged heating element 1. Replace fuse (0.8A/240V) 2. Cut power Supply and reconnect wiring 3. Reconnect control panel and reset 4. Controller (turn off and on) 1. Check whether the wire connector is dampened or damaged, and dry if dampened 2.
Type Power (KW) Voltage (V) Current (A) Errors Range Anti-Static Constant Insulation Resistance Head Lamp Temperature Range (°F) Time Set Range (min) Steam Press (psi) Steam Vol. (cu. in./min) Steam Spray Time (sec) Water Vol. (cu. in.) Applicable Space of the Room (cu. ft.) 4.5KW 6KW 7.5KW 9KW 10.5KW 12KW 15KW 4.5 240 19 +10% >1500V >20M Ω ~12V/3W 50-130 1-60 3 9 100-180 80 6 240 25 +10% >1500V >20M Ω ~12V/3W 50-130 1-60 4 11 180-240 160 7.
WIRING DIAGRAMS 4.5KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V~ Page 21 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.
6KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 22 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.
7.5KW & 9KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V~ Page 23 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.
10.5KW & 12KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 24 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.
15KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 25 SteamSpa PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com info@steamspa.