STEP ONE
Determine the installation location of the control panel. The master
control panel is designed to be installed in the steam room only, please
install:
1. 4-5 feet from the ground.
2. Keep away from the steam head and do not expose under the direct
spray of steam.
3. Install in the perpendicular wall.
4. The position of installation should facilitate easy operation and
convenient wiring.
The controller wire is 1.6 feet long with a controller lengthen wire of 20
feet max. The installation of the controller should be in a position not
more than 25 feet from the steam generator.
STEP TWO
Drill a round hole of 1 inch in diameter in a chosen position.
STEP THREE
Pull control panel wire inside steam room through opening connect it to
the lengthened wire and then to the steam generator and connect with
the corresponding wire in the generator. Connecting the wire of control
panel outside room to the wire of control panel inside the room. When
connecting wires please follow arrows on connector heads for proper
connection. Failure to do so will result in damaging of control pins.
STEP FOUR
Start the power supply of steam generator, check and adjust connection,
check each item on the page to make sure all functions work well.
IMPORTANT! Before adjusting the control panel, make sure the steam
generator is shut off otherwise the control panel may get damaged.
STEP FIVE
Remove the adhesive paper from Control Panel.
To achieve proper adhesion, make sure surface clean, dry and free of
dust.
IMPORTANT! Do not over extend or clip control panel wire as it may
cause possible damage.
STEP SIX
Run a bead of silicone around adhesive gasket. Press Control Panel
against wall at a 12 O’clock position until firmly adhered to surface.
IMPORTANT! Please do not apply an excessive amount of silicone. Just
enough to provide a moisture seal should suffice.
Extended wi re
Steam Generator
Control panel