INSTALLATION & USER GUIDE
PROLOGUE
Thank You for choosing SteamSpa for health, beauty and relaxation. Now you can enjoy your own private sanctuary in the comfort
of your own home. Let your stress melt away as you relax in your state of the art Steam Room.
WARRANTY
SteamSpa warrants that this steam bath generator unit will be free from manufacturer defects and malfunctions. For terms and
condition please refer to latest SteamSpa Warranty at www.SteamSpa.com/warranty.
Please be advised failure to comply with any of the following will VOID the warranty.
1. Generator and Use are registered within 90 days of delivery. See www.SteamSpa.com/register.
2. Installation must be performed by a licensed professional.
3. A quick release & pressure reducing valve must be used for reliable periotic maintenance.
4. An inline water filter must be installed to prevent mineral deposit and build up.
5. Filter cartridge must be replaced no later than every 6 months.
USER INSTRUCTIONS
1. Check for visible damages upon delivery of Generator. Any damages to packaging should be reported immediately to shipping
company delivery representative and SteamSpa’s Customer Service Dept.
2. Check model and accessories are correct, including voltage input. Any discrepancies are to be reported to SteamSpa’s
Customer Service Dept. within 48 hours of delivery.
3. Read installation instructions in detail for a secure and effective installation of SteamSpa generators.
4. SteamSpa recommends the use of a licensed plumber and electrician for proper installation of SteamSpa generators.
5. SteamSpa shall not be responsible for product damage or malfunction caused by self-installation or installation procedures
which do not comply with user manual.
6. SteamSpa generators are for indoor use only.
CHOOSING THE RIGHT LOCATION
1. The generator should be less than 25ft from the steam room for best performance.
2. The steam generator should not be installed in the steam room
3. Do not install outdoor or in any places that will influence the performance of the machine by the environment.
4. Do not install in a frigid location or any places where the water will freeze.
5. Do not install near flammable chemicals.
6. Install in a dry place where the ventilation is good.
7. Install an exhaust fan outside of the steam room for the excess steam to be expelled from the shower room.
8. The steam generator has a hanging groove for wall installations..
9. Both sides and the top of the steam generator need to reserve at least 12 inches space.
10. The area where the machine is installed must be easily cleaned up and convenient for the disassembly of the machine.
11. The installation area must be convenient for the steam generator draining system.
12. The steam tube, safety valve, drain valve, water tube and steam outlet remain very heated after the steam generator has
stopped working for some time.
13. The controller panel should be installed away from the steam head to avoid false readings,please read the instructions for the
controller’s installation and operation.