Mauritius 23000
Mauritius 180 230
10.0 0.20 -6 1.50
6 1.5 50
1.0 0.5 -3.0 0.5 no
Mexico 5200 Mexico 300 240
35.0 0.05 -50 0.10
10 600 -15 600 60
1.2 5.0 -1.2 5.0 yes
Netherlands
3100 Nederland 30 230
10.0 2.00 -20 2.00
50
1.0 2.0 -2.0 2.0 no
Austria 4300 Österreich 30 230 15.0 0.10 -20 0.20
12 600 50 1.5 0.2 -2.5 0.2 yes
Poland
4800 Polska 30 230
15.0 0.20 -15 1.50
10 600 50
1.0 0.5 -3.0 0.5 no
Portugal 35100
Portugal 20 230
15.0 0.20 -15 1.50
10 600 50
1.0 0.5 -3.0 0.5 no
Slovenia 38600
Slovenija 30 230
15.0 0.20 -30 0.20
10 1.5 -15 1.5 50
1.0 0.2 -3.0 0.2 no
South Africa 2700 South Africa 60 230
20.0 0.16 -50 0.20
10 2.0 -15 2.0 50
2.0 0.5 -2.5 0.5 no
Switzerland 4100 Suisse 30 230
15.0 0.20 -20 0.20
10 600 50
0.2 0.2 -2.5 0.2 no
Finland
35800
Suomi 30 230 10.0 0.20 -15 0.20
50 1.0 0.2 -2.0 0.2 no
Sweden 4600 Sverige 30 230 15.0 0.20 -15 0.20
11 60 50 1.0 0.5 -3.0 0.5 no
Tahiti
6890 Tahiti 60Hz 30 230
15.0 0.20 -20 0.20
10 600 60
2.5 0.2 -5.0 0.2 no
Taiwan 220 8860 Taiwan 300 230 10.0 0.20 -12 0.20
60 0.5 0.5 -0.5 0.5 no
Thailand MEA 6601 Thailand MEA 150 230 35.2 0.05 -50 0.10
4.3 2.0 -13 2.0 50
1.0 0.1 -1.0 0.1 no
Thailand PEA
6600 Thailand PEA 150 220 19.0 0.16 -50 0.30
10.2 1.0 -9.4 2.0 50 1.0 0.1 -2.0 0.1 yes
Turkey 9000 Türkiye 30 230
15.0 0.20 -20 0.20
10 600 50
0.2 0.2 -2.5 0.2 no
United Kingdom
G59/3
4401 UK (G59/3) 180 240 19.0 0.50 -20 0.50
14 1.0 -13 2.5 50 2.0 0.5 -3.0 0.5 no
United Kingdom
G83/1
4402 UK (G83/1) 20 230 14.7 1.50 -10 1.50
50 0.5 0.5 -3.0 0.5 no
United Kingdom
G83/2
4400 UK (G83/2) 20 230 19.0 0.50 -20 0.50
14 1.0 -13 2.5 50 2.0 0.5 -3.0 0.5 no
EN 50438:2014
50439
EN 50438:2014
60 230
15.0 0.20 -15 1.50
10 3.0 50
2.0 0.5 -2.5 0.5 no
Droop Mode
0007
Droop
-
Mode
50Hz
60 230 20.0 0.50 -20 0.50
50 5.0 0.5 -3.5 0.5 no
Droop Mode 60
0008
Droop
-
Mode
60Hz
60 230 20.0 0.50 -20 0.50
60 5.0 0.5 -3.5 0.5 no
1)
Country code and name as shown on the display.
2)
Disconnection values are upper and lower deviations from the peak values of the rated voltage (in %) and the associated switch-off time (in s).
3)
Disconnection values are upper and lower deviations from the average values of the rated voltage (in %) and the associated switch-off time (in s).
4)
Disconnection values are upper and lower deviations from the rated frequency (in Hz) and the associated switch-off time (in s).
5)
Maximum output power for StecaGrid 3600 and 4200: 3330 W.
6)
Maximum output power of all units expect StecaGrid 1500 and 1800: 2000 W.
7)
For systems smaller than 3 kW maximum power.
8)
For systems between 3 kW and 6 kW maximum power.
9)
Activation of DroopMode is recommended when the inverter is operated in conjunction with a stand-alone inverter. The system must not be connected to a
public electricity grid.