User manual
If the „Ch. Curve“ menu item is called, the inverter records the PV generator characteristic curve
and then displays it (Fig. upper left).
The following applies:
n The inverter traverses the input voltage range and records the power generated over this range.
Duration: a few seconds; is displayed.
n The MPP is at the peak of the PV generator characteristic curve.
n This peak and the PV generator characteristic curve change with the level of solar irradiation.
Information
The menu item Information contains the following sub-menu items.
n Contact info
n System info (see Fig. left):
– Product designation
– Serial number of the inverter
– Information concerning the software and hardware version of the inverter (see sample ①
in Fig. left)
– Inverter address
– Version of the manual that belongs with the inverter
n Country setting: country that is currently set and country-specific grid parameters; see also
Ä
Chapter 9.3 „Country table“ on page 92.
n Reactive power characteristic curve: Diagram of the reactive power characteristic
curve (only if prescribed for the set country)
n Network: Network parameters, partially configurable under Settings ▶ Network
– Host name: Unique name in the network
– DHCP status: DHCP on/off
– Link status: Status of the network connection
– IP address: IP address of the inverter
– Subnet mask: Subnet mask of the inverter
– Gateway: IP address of the network gateway
– DNS address: IP address of the DNS server
– MAC address: Hardware address of the inverter
n Results of the last self-test (only if in the country setting Italy is set)