User manual
Power limiter
The inverter output power can be manually limited to a minimum of 500 W. When the power is
manually limited, the Power reduction symbol is shown in the status display and the „Derating“ /
„Cause: User default“ measurement is displayed.
Fixed voltage
The device can regulate the input voltage to a manually adjustable value. This switches off the auto-
matic setting of the MPP (MPP tracking). The input voltage can be adjusted over a range between
the maximum and minimum input voltage and the minimum input voltage in 1V steps.
Exemplary application: Hydroelectric installation
NOTICE!
Before setting a fixed input voltage, make sure that the PV generator is suitable for this.
Otherwise, this may result in yield losses or damage to the system.
Delete country setting
After the country setting has been deleted the device restarts anew and displays the guided 1st
commissioning menu.