3.6.3 RS485 bus
The inverter communicates with other devices via an RS485 bus. The following applies: The fol-
lowing applies:
n The inverter has two RS485 interfaces (RJ45 sockets) on the lower side of the casing.
n The beginning and end of the RS485 bus must be terminated; see
Ä
Chapter 3.6.5 „RS485 ter-
mination“ on page 31.
n Standard RJ45 cables can be used as bus cables (Cat-5 patch cables, not supplied). Use an alter-
native data connection cable for longer connections; see
Ä
Chapter 3.6.4 „Alternative RS485
data connection cable“ on page 30.
n The inverters connected to the RS485 bus operate as slaves.
Notice
The following inverters have compatible data interfaces and can be connected to the RS485
bus as slaves:
StecaGrid 2020
StecaGrid 1500, 1800, 2000, 2300, 2500, 3010, 3000, 3600, 4200 and StecaGrid 1500,
1800x, 2000x, 2300x, 2500x, 3010x, 3000x, 3600x, 4200x
StecaGrid 8000 3ph, StecaGrid 10000 3ph
StecaGrid 8000+ 3ph, StecaGrid 10000+ 3ph
Comply with the instructions in the manuals of these devices relative to addressing, termina-
tion, and approved data cables.