3.6.3 RS485 bus
The inverter communicates with other devices via an RS485 bus. The following applies: The fol-
lowing applies:
n The inverter has two RS485 interfaces (RJ45 sockets) on the lower side of the casing.
n The beginning and end of the RS485 bus must be terminated; see
Ä
Chapter 3.6.5 „RS485 ter-
mination“ on page 31.
n Standard RJ45 cables can be used as bus cables (Cat-5 patch cables, not supplied). Use an alter-
native data connection cable for longer connections; see
Ä
Chapter 3.6.4 „Alternative RS485
data connection cable“ on page 30.
n The inverters connected to the RS485 bus operate as slaves.
Notice
The following inverters have compatible data interfaces and can be connected to the RS485
bus as slaves:
– StecaGrid 2020
– StecaGrid 1500, 1800, 2000, 2300, 2500, 3010, 3000, 3600, 4200 and StecaGrid 1500,
1800x, 2000x, 2300x, 2500x, 3010x, 3000x, 3600x, 4200x
– StecaGrid 8000 3ph, StecaGrid 10000 3ph
– StecaGrid 8000+ 3ph, StecaGrid 10000+ 3ph
Comply with the instructions in the manuals of these devices relative to addressing, termina-
tion, and approved data cables.