User manual

StecaGrid 1500/x StecaGrid 2000/x
Degree of protection coolcept: IP21 (housing: IP51; display: IP21)
coolcept-x: IP65
Overvoltage category III (AC), II (DC)
DC connection
Type Phoenix Contact SUNCLIX (1 pair)
Connection conductor cross-sec-
tion
Conductor cross-section 2.5 … 6 mm²
Opposing connector Opposing connector included in delivery
AC connection
Type Wieland RST25i3 plug
Connection cross sectionConnec-
tion conductor cross-section
Cable diameter 10 ... 14 mm
2
,
conductor cross-section ≤ 4 mm
2
Opposing connector Opposing connector included in delivery
Dimensions (X x Y x Z) coolcept: 340 x 608 x 222 mm
coolcept-x: 399 x 657 x 227 mm
Weight coolcept: 8,3 kg; coolcept-x: 11 kg
Display Graphical display, 128 x 64 pixels
Communication interfaces RS485 (2 x RJ45 sockets: Anschluss an Meteocontrol WEB‘log
oder Solar-Log™, 1 x RJ10 Buchse: Connection to Modbus RTU
counter), Ethernet interface (1 x RJ45)
Feed-in management as per
EEG 2012
EinsMan-ready, via RS485 interface
Integrated DC circuit breaker yes, compliant with VDE 0100-712
Cooling principle Temperature-controlled fan, speed variable, internal (dust-pro-
tected)
Test certificate Certificates download see the product page on our home-
page.
Technical data at 25 °C / 77 °F
1)
Due to its design the inverter cannot cause any DC fault currents.
9.1.2 StecaGrid 2500/2500x/3010/3010x
StecaGrid 2500/x StecaGrid 3010/x
DC input side (PV generator connection)
Number of DC inputs 1
EN
747.431 | Z09.3 | 2017-09-05
83