User manual

8 Maintenance and disposal
8.1
Maintenance
The inverter is basically maintenance-free. Despite this, it is a good idea to regularly check that the
cooling fins on the front and rear sides of the device are free of dust. Clean the inverter when neces-
sary as described below.
ATTENTION!
Danger of destruction of components in devices of type
coolcept:
Do not allow cleaning agents and devices to penetrate between the cooling fins at the front
of the inverter (under the grey hood).
Do not use especially the following cleaning agents:
Solvent-based cleaning agents
Disinfection agents
Coarse or sharp-edged cleaning agents
Removing dust
Dust should be removed using compressed air (max. 2 bar).
Removing heavy soiling
DANGER!
Risk of death by electrocution! Use cleaning agents only with a slightly damp cloth.
1. Remove heavy soiling with a slightly damp cloth (use clear water). If necessary, use a 2 %
hard soap solution instead of water.
2. After cleaning, remove any soap residue using a slightly damp cloth.
8.2
Disposal
Do not dispose of the device in the normal household waste. At the end of its service life, return the
device to Steca Customer Service with a note stating
Zur Entsorgung (For disposal)
.
The device packaging consists of recyclable materials.
GB
747.431 | Z08 | 2014-01-31
132