Display Parameters min. max.
Factory 
setting
Functionality
T
T
P
ara
SET
Storage tank loading 
strategy
dIFF
 1)
, AbS
2)
The loading strategy depends 
on the storage tank system 
used and the usage of the 
system.
dIFF: Highest efficiency. The 
control target is the tem-
perature difference between 
the collector and the storage 
tank.
 3)
AbS: Useful when the system 
requires particular tempera-
tures, e.g. to avoid switching 
on the external back-up heat-
ing system.
The control target is the tem-
perature of the collector.
 3)
Control target of dif-
ferential temperature 
loading (dIFF)
2 K 50 K 8 K
Control target of 
absolute temperature 
loading (AbS)
0 °C 95 °C 60 °C
P
ara
SET
R1 pump type AC, HE
AC
Notice
Danger of malfunctions in the 
controller or damage to the 
components. 
With a high-efficiency pump, 
HE must be set and with a 
standard pump AC must be 
set! 
Set speed control to oFF 
when an external relay is con-
nected or speed control is not 
wanted.
Pump characteris-
tics (only HE)
AA, Ab, C (see p. 15) –
Speed control on, oFF
oFF
Minimum speed 
(only AC)
30 % 100 % 50 %
Minimum speed 
(only HE + AA)
0 % 100 % 25 %
Minimum speed 
(only HE + Ab)
0 % 100 % 75 %
Tab. 3:  Parameters
1)
  dIFF is defined as a fixed value for swimming pools.
2)
  The factory setting depends on the system that has been set.
3)
  The pump speed is adjusted accordingly to achieve the control target.