Cut Sheet
Table Of Contents
- Table of Contents
- Overview
- Thinwall Conduit Fittings (EMT)
- Rigid/Intermediate Grade Conduit Fittings
- Flexible Cord and Power Cable Connectors
- Liquidtight Flexible Metal Conduit and Connectors
- Non-Metallic Sheathed Cable Fittings
- Armored Cable/Flexible Metallic Conduit Fittings
- Service Caps
- Cable Caps, Protector, Straps and Clips; Threaded Rod and Coupling
- Beam Clamps
- Ground Clamps, Pipe Hangers
- PVC Conduit Repair System
- Schedule 40 & 80 Elbows
- Schedule 40 & 80 Fittings & Accessories
- Conduit Bodies & Accessories
- Junction Boxes
- Switch Boxes
- Support Straps
- Conduit Clamps
- Schedule 40 & 80 Tech Specs
- Utility Conduit
- P&C Duct
- Telephone Duct
- Split Duct
- Accessories
- Spacers
- P&C Flex™
Rigid/Intermediate Grade Conduit Fittings
F-14
Fittings
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B CTN.
BU-401
1
⁄2 1
1
⁄32
7
⁄16 1,000
BU-402
3
⁄4 1
1
⁄4
7
⁄16 1,000
BU-403 11
9
⁄16
1
⁄2 500
BU-404 1
1
⁄4 1
15
⁄16
17
⁄32 200
BU-405 1
1
⁄2 2
13
⁄64
9
⁄16 100
BU-406 22
45
⁄64
9
⁄16 50
UL File No. E-23018.
TRADE GROUNDING LUG WIRE SIZE STD.
CAT. NO.
SIZE (IN.) MIN. MAX. CTN.
BG201
1
⁄2 14 4 500
BG-202
3
⁄4 14 4 500
BG-203 1 14 4 250
BG-204A 1
1
⁄4 14 4 200
BG-204 1
1
⁄4 8 1/0 200
BG-205A 1
1
⁄2 11 4 100
BG-205 1
1
⁄2 81/0 50
BG-206A 1 14 4 100
BG-206 2 8 1/0 50
UL File No. E-3060.
• 105° C thermoplastic liners
• Heavy reinforced ribs
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B CTN.
BU-801
1
⁄2 1.06 0.43 1,000
BU-802
3
⁄4 1.31 0.43 1,000
BU-803 1 1.59 0.48 500
BU-804 1
1
⁄4 1.96 0.56 250
BU-805 1
1
⁄2 2.18 0.60 250
UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) B (MAX.) CTN.
BU201
1
⁄2 1.05 0.37 1,000
BU-202
3
⁄4 1.32 0.37 1,000
BU-203 1 1.58 0.47 500
BU-204 1
1
⁄4 1.94 0.50 250
BU-205 1
1
⁄2 2.20 0.52 250
UL File No. E-23018.
A
B
Conduit Bushings Die Cast
Zinc — Heavy Reinforced Ribs
Grounding Bushings
Die Cast Zinc — Insulated
Metallic With Aluminum
Lay-in Type Lug
A
B
A
B
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B CTN.
BU-501
1
⁄2
13
⁄32 1
1
⁄16 400
BU-502
3
⁄4
13
⁄32 1
19
⁄64 400
BU-503 1
9
⁄16 1
9
⁄16 200
BU-504 1
1
⁄4
9
⁄16 1
29
⁄32 100
BU-505 1
1
⁄2
9
⁄16 2
3
⁄16 100
BU-506 2
5
⁄8 2
11
⁄16 60
UL File No. E-23018
1
⁄
2
"–4" only.
Rated 105° C.
Insulated Bushings —
Thermoplastic
Bushings — Iron/Zinc Plated
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B CTN.
BU-806 2 2.68 0.56 250
BU-807 2
1
⁄2 3.25 0.90 50
BU-808 3 3.87 0.85 25
BU-809 3
1
⁄2 4.37 0.93 25
BU-810 4 5.00 0.93 10
UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) B (MAX.) CTN.
BU-206 2 2.69 0.52 250
BU-207 2
1
⁄2 3.23 0.85 50
BU-208 3 3.84 0.85 25
BU-209 3
1
⁄2 4.35 0.85 25
BU-210 4 5.02 0.85 10
UL File No. E-23018.
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B CTN.
BU-507 2
1
⁄2
23
⁄32 3
3
⁄16 20
BU-508 3
9
⁄16 3
27
⁄32 20
BU-509 3
1
⁄2
3
⁄4 4
23
⁄64 5
BU-510 4
25
⁄32 4
27
⁄32 5
BU-511 516
5
⁄16 5
BU-512 617
7
⁄16 5
UL File No. E-23018
1
⁄
2
"–4" only.
Rated 105° C.
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B CTN.
BU-407 2
1
⁄2 3
3
⁄16
11
⁄32 30
BU-408 33
5
⁄8
25
⁄32 25
BU-409 3
1
⁄2 4
1
⁄16
27
⁄32 25
BU-410 44
21
⁄32
15
⁄16 25
BU-411 54
21
⁄32
15
⁄16 10
UL File No. E-23018.
TRADE GROUNDING LUG WIRE SIZE STD.
CAT. NO.
SIZE (IN.) MIN. MAX. CTN.
BG-207 2
1
⁄2 81/0 50
BG-207A 2
1
⁄2 6 250 kcmil 50
BG-208 3 8 1/0 50
BG-208A 3 6 250 kcmil 50
BG-209 3
1
⁄2 81/0 10
BG-209A 3
1
⁄2 6 250 kcmil 10
BG-210 4 8 1/0 10
BG-210A 4 6 250 kcmil 10
UL File No. E-3060.
A
B
• 105°C thermoplastic
liners
• Heavy reinforced ribs
Conduit Bushings
Die Cast Zinc —
Insulated Metallic