Cut Sheet
Table Of Contents
- Table of Contents
- Overview
- Thinwall Conduit Fittings (EMT)
- Rigid/Intermediate Grade Conduit Fittings
- Flexible Cord and Power Cable Connectors
- Liquidtight Flexible Metal Conduit and Connectors
- Non-Metallic Sheathed Cable Fittings
- Armored Cable/Flexible Metallic Conduit Fittings
- Service Caps
- Cable Caps, Protector, Straps and Clips; Threaded Rod and Coupling
- Beam Clamps
- Ground Clamps, Pipe Hangers
- PVC Conduit Repair System
- Schedule 40 & 80 Elbows
- Schedule 40 & 80 Fittings & Accessories
- Conduit Bodies & Accessories
- Junction Boxes
- Switch Boxes
- Support Straps
- Conduit Clamps
- Schedule 40 & 80 Tech Specs
- Utility Conduit
- P&C Duct
- Telephone Duct
- Split Duct
- Accessories
- Spacers
- P&C Flex™
Non-Metallic Sheathed Cable Fittings
F-25
Fittings
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B C D E CTN.
NC-850
1
⁄2 .050 .950 1.312 .650 8–32 x
3
⁄4 1,000
NC-851
3
⁄4–1 .050 1.250 1.750 .760 8–32 x 1 500
NC-852 1–
1
⁄4 .062 1.625 2.125 .760 10–32 x 1 250
NC-853 1–
1
⁄2 .062 1.970 2.500 .785 10–32 x 12 100
A
B
D
C
E
A Max.
A Min.
DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-2200-C
3
⁄8 0.12 0.63 0.98 500
B
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) A (MAX.) B CTN.
NC-201
1
⁄2 0.40 0.95 1.87 250
NC-202
3
⁄4 0.50 1.10 1.84 200
NC-203 1 0.62 1.14 2.00 100
NC-204 1
1
⁄4 0.50 1.38 2.28 100
NC-205 1
3
⁄8 0.75 1.61 2.49 50
NC-206 2 0.90 2.04 3.35 50
CSA File No. LR-12798.
UL File No. E-17583.
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) A (MAX.) B CTN.
NC041 1
1
⁄4 0.27 0.75 2.02 100
NC-051 1
1
⁄2 0.54 0.95 2.50 50
NC-061 2 0.75 1.12 3.41 40
UL File No. E-15170 — 1
1
⁄
4
"–1
1
⁄
2
".
UL File No. E-17583 — 2".
1–1
1
⁄16"
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) A (MAX.) B CTN.
XC-210
3
⁄8 (
1
⁄2 KO) 0.13 0.65 1.56 250
XC-211-SC
3
⁄8 0.24 0.63 1.59 200
XC-222-SC
3
⁄8 0.24 0.63 1.59 200
CONDUIT/CABLE FMC (IN.) AC MCC MCI
Max. Size
3
⁄8 10/2 .565 .565
Min. Size
3
⁄8 14/2 .425 .425
CSA File No. LR-12798.
UL File No. E1383.
B
A Max.
A Min.
• For use with
aluminum, smooth,
extruded metal–clad
cable. (min. dia. .410
— max. dia. .500).
NM Clamp Type
Connector —
Die Cast Zinc
B
A Max.
A Min.
B
A Max.
A Min.
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A (MIN.) A (MAX.) B CTN.
NC301
3
⁄8 (
1
⁄2 KO) 0.18 0.64 1.16 1,000
NC-302
3
⁄4 0.41 0.82 1.87 500
NC-303 1 0.34 0.94 2.01 250
CSA File No. LR-12798.
UL File No. E-17583.
Connectors Clamp Type
Non-Watertight —
Die Cast Zinc
Duplex Clamp
Type Connector —
Die Cast Zinc
NM Flex Connectors
Saddle Type —
Die Cast Zinc
Tilt-In Connector
Metallic Steel —
Electro-Galvanized
Clamp Type
Connector —
Die Cast Zinc