Cut Sheet
Table Of Contents
- Table of Contents
- Overview
- Thinwall Conduit Fittings (EMT)
- Rigid/Intermediate Grade Conduit Fittings
- Flexible Cord and Power Cable Connectors
- Liquidtight Flexible Metal Conduit and Connectors
- Non-Metallic Sheathed Cable Fittings
- Armored Cable/Flexible Metallic Conduit Fittings
- Service Caps
- Cable Caps, Protector, Straps and Clips; Threaded Rod and Coupling
- Beam Clamps
- Ground Clamps, Pipe Hangers
- PVC Conduit Repair System
- Schedule 40 & 80 Elbows
- Schedule 40 & 80 Fittings & Accessories
- Conduit Bodies & Accessories
- Junction Boxes
- Switch Boxes
- Support Straps
- Conduit Clamps
- Schedule 40 & 80 Tech Specs
- Utility Conduit
- P&C Duct
- Telephone Duct
- Split Duct
- Accessories
- Spacers
- P&C Flex™
Ground Clamps, Pipe Hangers
F-34
Fittings
For hanging conduit (rigid or EMT) and pipe.
The 6H series hangers are fast, easy and economical
to use. May be fastened directly to a #500 beam
clamp through a hole in the base of the hanger by
means of a 1⁄4-20 stove bolt or suspended on
1
⁄4"
hanger rod.
All Steel City 6H Hanger Bolts include
a combination Slot-Phillips Head.
-
6H Without bolt.
6H-B With bolt
and hex nut.
6H-T Threaded
without bolt.
6H-TB Threaded
with bolt.
D Dia.
6H Series Conduit and Pipe Hangers — With Bolt
RIGID CONDUIT
OR PIPE EMT DIMENSIONS (IN.) LOAD STD.
CAT. NO.
SIZE (IN.) SIZE (IN.) A B C D (DIA.) RATING CTN.
6H0 B
3
⁄8–
1
⁄2
1
⁄2
3
⁄4 .045 1
21
⁄32
9
⁄32 500 100
6H0 TB
3
⁄8–
1
⁄2
1
⁄2
3
⁄4 .045 1
27
⁄32
9
⁄32 500 100
6H1-B
3
⁄4
3
⁄4
7
⁄8 .045 1
31
⁄32
9
⁄32 500 100
6H1-TB
3
⁄4
3
⁄4
7
⁄8 .045 2
9
⁄32
9
⁄32 500 100
6H2-B 11
7
⁄8 .045 2
3
⁄8
9
⁄32 500 100
6H2-B 11
1
⁄4
7
⁄8 .045 2
23
⁄32
9
⁄32 500 100
6H3-B 1
1
⁄4 1
1
⁄2
7
⁄8 .045 2
7
⁄8
9
⁄32 500 100
6H4-B 1
1
⁄2 — 1 .071 3
3
⁄8
11
⁄32 500 100
6H5-B 221
1
⁄4 .071 3
29
⁄32
11
⁄32 500 50
6H6-B 2
1
⁄2 —1
1
⁄4 .071 4
9
⁄32
11
⁄32 500 50
6H7-B 3—1
1
⁄4 .071 5
3
⁄16
11
⁄32 500 25
6H8-B 3
1
⁄2 —1
1
⁄4 .071 5
7
⁄16
11
⁄32 500 25
6H9-B 441
1
⁄4 .071 5
7
⁄8
11
⁄32 500 10
UL File No. E-160899.
Add SS suffix to part number for Stainless Steel.
Load rating is 500 lbs. with a safety factor of 3.
Available with or without closure bolt.
Standard finishes: Electro-Galvanized. (Add SS suffix for Type 302 Stainless Steel)
6H Series Conduit and Pipe Hangers — Without Bolt
RIGID CONDUIT
OR PIPE EMT DIMENSIONS (IN.) LOAD STD.
CAT. NO.
SIZE (IN.) SIZE (IN.) A B C D (DIA.) RATING CTN.
6H0
3
⁄8–
1
⁄2
1
⁄2
3
⁄4 .045 1
21
⁄32
9
⁄32 500 100
6H0 T
3
⁄8–
1
⁄2
1
⁄2
3
⁄4 .045 1
27
⁄32
9
⁄32 500 100
6H1
3
⁄4
3
⁄4
7
⁄8 .045 1
31
⁄32
9
⁄32 500 100
6H1-T
3
⁄4
3
⁄4
7
⁄8 .045 2
9
⁄32
9
⁄32 500 100
6H2 11
7
⁄8 .045 2
3
⁄8
9
⁄32 500 100
6H2 1/2 — 1
1
⁄4
7
⁄8 .045 2
23
⁄32
9
⁄32 500 100
6H3-SC 1
1
⁄4 1
1
⁄2
7
⁄8 .045 2
7
⁄8
9
⁄32 500 100
6H4 1
1
⁄2 — 1 .071 3
3
⁄8
11
⁄32 500 100
6H5 221
1
⁄4 .071 3
29
⁄32
11
⁄32 500 50
6H6 2
1
⁄2 —1
1
⁄4 .071 4
9
⁄32
11
⁄32 500 50
6H7 3—1
1
⁄4 .071 5
3
⁄16
11
⁄32 500 25
6H8 3
1
⁄2 —1
1
⁄4 .071 5
7
⁄16
11
⁄32 500 25
6H9 441
1
⁄4 .071 5
7
⁄8
11
⁄32 500 10
UL File No. E-160899.
Add SS suffix to part number for Stainless Steel.
Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt.
Standard finishes: Electro-Galvanized. (Add SS suffix for Type 302 Stainless Steel)
Without Bolt
CONDUIT STD.
CAT. NO.
SIZE (IN.) CTN.
GC-203-B
1
⁄2; 1 200
Ground Clamps — Die Cast
Zinc, Brass Colored
• Two-screw ground connection
for armored ground wire