Cut Sheet
Table Of Contents
- Table of Contents
- Overview
- Thinwall Conduit Fittings (EMT)
- Rigid/Intermediate Grade Conduit Fittings
- Flexible Cord and Power Cable Connectors
- Liquidtight Flexible Metal Conduit and Connectors
- Non-Metallic Sheathed Cable Fittings
- Armored Cable/Flexible Metallic Conduit Fittings
- Service Caps
- Cable Caps, Protector, Straps and Clips; Threaded Rod and Coupling
- Beam Clamps
- Ground Clamps, Pipe Hangers
- PVC Conduit Repair System
- Schedule 40 & 80 Elbows
- Schedule 40 & 80 Fittings & Accessories
- Conduit Bodies & Accessories
- Junction Boxes
- Switch Boxes
- Support Straps
- Conduit Clamps
- Schedule 40 & 80 Tech Specs
- Utility Conduit
- P&C Duct
- Telephone Duct
- Split Duct
- Accessories
- Spacers
- P&C Flex™
Thinwall Conduit Fittings (EMT)
F-5
Fittings
CONDUIT INNER OUTER
“A” CAT NO.
SIZE (IN.) PACK PACK
TK111A
1
⁄2 50 250
TK112A
3
⁄4 50 250
TK113A 1 25 100
TK114A 1
1
⁄4 —25
TK115A 1
1
⁄2 —25
TK116A 2—25
TK117A 2
1
⁄2 —10
TK118A 3—5
TK119A 3
1
⁄2 —5
TK1110A 4—5
Steel City
®
Raintight EMT Compression Fittings
feature a distinctive design and a vibrant gold
gland nut, enabling inspectors to visually inspect
conformance from a distance. There’s no close-
up inspection required!
CAT. NO.
DESCRIPTION STD. CTN.
TC101-SC
1
⁄2" Uninsulated 500
TC-102-SC
3
⁄4" Uninsulated 250
TC-701-SC
1
⁄2" Insulated 500
TC-702-SC
3
⁄4" Insulated 250
UL Listing No. E16592, CSA Listing No. LR-12798.
Installation using either slotted or Phillips screwdriver head,
35-in-lb of torque onto the EMT.
NOTE: Excessive torque could damage EMT or housing.
• Simple, one-piece installation with no locknuts
• Available in insulated or non-insulated throat
• Screw designed for exceptional pullout resistance
• Captive screw ensures that the screw is intact for installation
and resists backing out after installa
tion
• Corrosion-resistant, zinc-chromatic plating
• Positive grounding
• Vibration-resistant screw design
• UL listed and CSA certified
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B C CTN.
LTT 111
1
⁄2 EMT to
1
⁄2 Liquidtight
1
3
⁄4
15
⁄16 1
1
⁄8
100
LTT-112
3
⁄4 EMT to
3
⁄4 Liquidtight
1
3
⁄4 1
11
⁄64 1
3
⁄8
50
LTT-113 1 EMT to 1 Liquidtight
1
15
⁄16 1
1
⁄2 1
3
⁄4
25
CONDUIT DIMENSIONS (IN.) STD.
CAT. NO.
SIZE (IN.) A B C CTN.
LTH 111
1
⁄2 Rigid to
1
⁄2 Liquidtight 1
7
⁄8 1
1
⁄8 1
1
⁄8 100
A
C
Corner
B
Corner
A
C
Corner
B
Corner
• Steel
• Raintight
• Zinc plated
UL File No. E-16592.
CONDUIT INNER OUTER
“A” CAT NO.
SIZE (IN.) PACK PACK
TK111A-RT
1
⁄2 50 250
TK112A-RT
3
⁄4 50 250
TK113A-RT 1 25 100
TK114A-RT 1
1
⁄4 —25
TK115A-RT 1
1
⁄2 —25
TK116A-RT 2—25
TK117A-RT 2
1
⁄2 —10
TK118A-RT 3—5
TK119A-RT 3
1
⁄2 —5
TK1110A-RT 4—5
UL File No. E-16592.
Compression
Couplings —
Steel
• Steel
• Raintight
• Zinc plated
EMT LOK Conduit Connector — Steel
Combination Compression Couplings — Heavywall to Liquidtight Flexible Metal Conduit — Steel
Combination Compression Couplings — Thinwall to Liquidtight Flexible Metal Conduit — Steel
•
1
⁄2"–4"
concrete
tight
• Zinc plated
• RT — Raintight