F-73
Non-Metallic Rigid Conduit, Fittings and Accessories
Accessories — PVC Cements
No waste • Sprays on in seconds • Fast setting
Multi-Purpose Spray-On PVC Cement
• Equivalent to a medium-bodied low-VOC,
quick-setting clear cement
• No more spills
• Reuse can until empty
• Installation: 50° to 80°F; Storage: 35° to 120°F
• Meets ASTM D-2564
• 3-year shelf life
• One 4 oz. can is equivalent to 4 oz. of non-aerosol PVC cement*
*Equivalence is subject to usage and will vary.
• For use up to 4" diameter
Schedule 40 or 80 PVC
electrical conduit
• For use with PVC Raceways
only. Not recommended for
use on water, sewer, natural
gas, compressed gas or
air connections
Applications:
STD. STD. WT.
CAT. NO.
SIZE DESCRIPTION CTN. (LBS.)
VC9AC5 4 oz. PVC Spray-On Medium Clear 12 5.6
VC9AC5C 4 oz. PVC Spray-On Medium Clear 12 5.6
VC9AC16 11 oz. PVC Spray-On Medium Clear 12 12.3
VC9AC16C 11 oz. PVC Spray-On Medium Clear 12 12.3
Recommended set time may vary depending on humidity.
Canada only
RECOMMENDED SET TIME
TEMPERATURE PIPE SIZES PIPE SIZES PIPE SIZES
RANGE
1
⁄2" TO 1
1
⁄4"1
1
⁄2" TO 2" 2
1
⁄2" TO 4"
60°–100°F 2 min. 5 min. 30 min.
40°–60°F 5 min. 10 min. 2 hrs.
0°–40°F 10 min. 15 min. 12 hrs.
Low VOC — Gray
RECOMMENDED PIPE SET-UP TIME RECOMMENDED LAP SHEAR VISCOSITY AT 75˚
APPLICATION AND SIZES (EVAPORATION RATE) INSTALLATION TEMP. @ 73˚F AS MANUFACTURED
10˚–30˚F Not recommended 40˚ to 100˚F 2 hrs. 350 psi 500–900 cps
30˚–50˚F 5–6 minutes 16 hrs. 800 psi
50˚–70˚F 3–4 minutes 72 hrs. 1,500 psi
70˚–90˚F 1–2 minutes
STD. STD. WT.
CAT. NO.
SIZE APPLICATOR DESCRIPTION CTN. (LBS.)
VC9LV4-24
1
⁄2 Pint Dauber Low VOC Gray 24 15.5
VC9LV3 Pint Dauber Low VOC Gray 24 27.0
VC9LV2 Quart Dauber Low VOC Gray 12 26.0
Recommended for all grades and
types of Carlon
®
wireway and fittings,
except Flex-Plus
®
Blue
™
ENT
(Electrical Non-Metallic Tubing).
Up through 6" diameter.
VOC emission of 490 grams/liter per
the Bay and South Coast test method.
Meets ASTM D-2564