Cut Sheet

F-89
Non-Metallic Rigid Conduit, Fittings and Accessories
P&C Flex
PERFORMANCE PROPERTIES
3
4"1"1
1
4"1
1
2"2"2
1
2"3" 4"
Stiffness F/ y at 5% deflection 200 200 200 200 200 130 130 90
Impact Strength (ft./lbs.) 72° 35 40 40 50 50 70 120 140
Impact Strength (ft./lbs.) 32° 5 8 8 15 25 35 60 60
Minimum Bending Radius (inches) 6 6 6 7 8 12 15 18
Conduit Tensile Strength 200 300 400 500 700 1000 1500 2000
Storage: -4° to 158°F
Handling: -4° to 104°F
Technical Information
RADIUS
18" REQUIRED 24" REQUIRED 36" REQUIRED 48" REQUIRED 60" REQUIRED
(IN.)
LENGTH OF P&C LENGTH OF P&C LENGTH OF P&C LENGTH OF P&C LENGTH OF P&C
NOM. DIA.
SEGMENT FLEX (IN.) FLEX (IN.) FLEX (IN.) FLEX (IN.) FLEX (IN.)
90º 33 42 61 80 99
45º 19 23 33 42 52
1
1
2 30º 14 17 23 30 36
22
1
2º12 14 19 23 28
90º 32 42 61 79 98
45º 18 23 32 42 51
2
30º 14 17 23 29 35
22
1
2º11 12 18 23 28
90º 34 44 63 81 100
45º 20 25 33 44 53
2
1
2
30º 16 19 24 31 37
22
1
2º13 15 20 25 30
90º 35 44 63 82 101
45º 20 25 34 44 53
3
30º 16 19 24 32 38
22
1
2º13 16 20 25 30
90º 37 46 65 84 103
45º 22 27 37 46 55
4
30º 18 21 27 34 40
22
1
2º15 18 22 27 32
For other radius sweeps use this formula: .0175 x Radius (inches) x Angle° = Required length of P&C flex in inches
Sweep and Elbow Conversion Chart